All MIBs › LLDP-EXT-DOT1-V2-MIB › lldpXdot1dcbxLocPFCWilling
lldpXdot1dcbxLocPFCWilling
Module: LLDP-EXT-DOT1-V2-MIB
OID (symbolic): LLDP-EXT-DOT1-V2-MIB::lldpXdot1dcbxLocPFCWilling
OID (numeric): 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1.1.1
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-only
Description: Indicates if the local system is willing to accept the PFC configuration of the remote system.
What is lldpXdot1dcbxLocPFCWilling?
This read-only truth value reports whether the local system is willing to accept the Priority-based Flow Control configuration recommended by its link partner rather than enforcing its own PFC settings. Admins check it to understand whether PFC priority selection on this port will be dictated locally or negotiated from the remote side during DCBX exchange. A false value means the local PFC configuration takes precedence.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1.1.1 snmpwalk -v2c -c public <target> LLDP-EXT-DOT1-V2-MIB::lldpXdot1dcbxLocPFCWilling
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1.1.1.1 snmpget -v2c -c public <target> LLDP-EXT-DOT1-V2-MIB::lldpXdot1dcbxLocPFCWilling.1
Start monitoring Network device implementing IEEE 802.1AB LLDP (802.1 extension TLVs) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LLDP-EXT-DOT1-V2-MIB::lldpXdot1dcbxLocPFCWilling OID value, configure state conditions and alerts, and monitor any Network device implementing IEEE 802.1AB LLDP (802.1 extension TLVs) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.111.2.802.1.1 | ieee802dot1mibs | IEEE8021-TC-MIB |
| 1.3.111.2.802.1.1.13 | lldpV2MIB | LLDP-V2-MIB |
| 1.3.111.2.802.1.1.13.1 | lldpV2Objects | LLDP-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5 | lldpV2Extensions | LLDP-V2-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.111.2.802.1.1.13.1.5.32962 | lldpV2Xdot1MIB | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5 | lldpXdot1dcbxMIB | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1 | lldpXdot1dcbxObjects | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1.2 | lldpXdot1dcbxLocalData | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3 | lldpXdot1dcbxLocPFC | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1 | lldpXdot1dcbxLocPFCBasicTable | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1.1 | lldpXdot1dcbxLocPFCBasicEntry | LLDP-EXT-DOT1-V2-MIB |
| 1.3.111.2.802.1.1.13.1.5.32962.5.1.2.3.1.1.1 | lldpXdot1dcbxLocPFCWilling | LLDP-EXT-DOT1-V2-MIB |