Access: read-only

Description: number of notification messages

What is notificationMessageCount?

This object reports the total count of notification messages currently held by the LeftHand Networks storage system's notification log. Administrators check this value to get a quick sense of how many alerts or events are queued up for review, for example after returning from time away to see if anything needs attention. For example, seeing this object jump from 2 to 15 overnight would tell an admin that a burst of new notifications, such as disk or replication alerts, arrived and should be reviewed in the notification table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.13.1
snmpwalk -v2c -c public <target> LEFTHAND-NETWORKS-NUS-COMMON-NOTIFICATION-MIB::notificationMessageCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.13.1.1
snmpget -v2c -c public <target> LEFTHAND-NETWORKS-NUS-COMMON-NOTIFICATION-MIB::notificationMessageCount.1

Start monitoring HP/LeftHand Networks storage appliances with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LEFTHAND-NETWORKS-NUS-COMMON-NOTIFICATION-MIB::notificationMessageCount OID value, configure state conditions and alerts, and monitor any HP/LeftHand Networks storage appliances from a single console.

How to Use in IPNetwork Monitor

Select a HP/LeftHand Networks storage appliance as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type notificationMessageCount into the Find box to locate it in the OID tree, then select it and click OK. It reports number of notification messages. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9804leftHandNetworksLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3lhnProductsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1lhnNusDevicesMIBsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1lhnNusCommonMIBLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1.2lhnNsmObjectsLEFTHAND-NETWORKS-NSM-MIB
1.3.6.1.4.1.9804.3.1.1.2.13lhnNsmOldNotificationLEFTHAND-NETWORKS-NSM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9804.3.1.1.2.13.1notificationMessageCountLEFTHAND-NETWORKS-NUS-COMMON-NOTIFICATION-MIB