LEFTHAND-NETWORKS-NSM-NETWORK-MIB :: networkDeviceCount

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LEFTHAND-NETWORKS-NSM-NETWORK-MIB › networkDeviceCount

networkDeviceCount

Module: LEFTHAND-NETWORKS-NSM-NETWORK-MIB

OID (symbolic): LEFTHAND-NETWORKS-NSM-NETWORK-MIB::networkDeviceCount

OID (numeric): 1.3.6.1.4.1.9804.3.1.1.2.2.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of network devices.

What is networkDeviceCount?

This object reports the total number of network device entries, such as NICs, bonds, or other network interfaces, present in the networkDeviceTable on this SAN/iQ storage node. Admins use it as a quick sanity check on how many network interfaces the storage system currently reports, useful when verifying bonded or redundant NIC configurations came up correctly. For example, a value of 4 confirms the storage node currently has four network device entries, matching an expected configuration of two physical NICs plus two bonded or virtual interfaces.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.2.1
snmpwalk -v2c -c public <target> LEFTHAND-NETWORKS-NSM-NETWORK-MIB::networkDeviceCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9804.3.1.1.2.2.1.1
snmpget -v2c -c public <target> LEFTHAND-NETWORKS-NSM-NETWORK-MIB::networkDeviceCount.1

Start monitoring HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ network interfaces) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LEFTHAND-NETWORKS-NSM-NETWORK-MIB::networkDeviceCount OID value, configure state conditions and alerts, and monitor any HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ network interfaces) from a single console.

How to Use in IPNetwork Monitor

Select an HP StorageWorks P4000 SAN storage node (LeftHand SAN/iQ network interfaces) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type networkDeviceCount into the Find box to locate it in the OID tree, then select it and click OK. The number of network devices. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9804leftHandNetworksLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3lhnProductsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1lhnNusDevicesMIBsLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1lhnNusCommonMIBLEFTHAND-NETWORKS-GLOBAL-REG
1.3.6.1.4.1.9804.3.1.1.2lhnNsmObjectsLEFTHAND-NETWORKS-NSM-MIB
1.3.6.1.4.1.9804.3.1.1.2.2lhnNsmNetworkLEFTHAND-NETWORKS-NSM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.9804.3.1.1.2.2.1networkDeviceCountLEFTHAND-NETWORKS-NSM-NETWORK-MIB