LB3GH-1-0-7 :: chassisAction

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › LB3GH-1-0-7 › chassisAction

chassisAction

Module: LB3GH-1-0-7

OID (symbolic): LB3GH-1-0-7::chassisAction

OID (numeric): 1.3.6.1.4.1.43.7.1.1.13

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This object, when read, always returns the value other (1). The result of setting this object to each acceptable value is:

reset: resets the LinkBuilder 3GH system.

What is chassisAction?

A write-only control point: reading it always returns other(1), but setting it to reset(2) remotely reboots the LinkBuilder 3GH chassis, e.g. to recover a hung unit without a site visit. Deprecated in favor of the equivalent lbSystemAction.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.43.7.1.1.13
snmpwalk -v2c -c public <target> LB3GH-1-0-7::chassisAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.43.7.1.1.13.1
snmpget -v2c -c public <target> LB3GH-1-0-7::chassisAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.43.7.1.1.13.1 i <value>

Start monitoring 3Com LinkBuilder hub/FDDI concentrator chassis with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LB3GH-1-0-7::chassisAction OID value, configure state conditions and alerts, and monitor any 3Com LinkBuilder hub/FDDI concentrator chassis from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.43a3ComA3COM-AUDL-R1-MIB
1.3.6.1.4.1.43.7linkBuilder3GH_mibA3Com-products-MIB
Numeric OIDNameModule
1.3.6.1.4.1.43.7.1lb3ghMibLB3GH-1-0-7
1.3.6.1.4.1.43.7.1.1chassisLB3GH-1-0-7
1.3.6.1.4.1.43.7.1.1.13chassisActionLB3GH-1-0-7