Description: A reporting threshold for the total number of addresses known for the bridge identified by this entry. When this threshold is reached, the event lpsBridgeAddressThresholdEvent is generated. The range of valid values for setting this object is between 1 and the corresponding value reported by lpsBridgeAddressTableSize + 1 (Note that this range applies to values issued in set requests. The current value may be outside this range, for example if the corresponding value of lpsBridgeMode is changed). Setting this object to one greater than the address table size disables the generation of lpsBridgeAddressThresholdEvents since the limit will never be reached.

What is lpsBridgeAddressThreshold?

A read-write reporting threshold, from 1 up to the address table size plus one, that fires an lpsBridgeAddressThresholdEvent once the bridge's learned-address count reaches it; setting it one above the table size disables the alert entirely. An admin lowers this to get early warning before the address table actually fills and the bridge starts flooding unknown-destination traffic.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.114.1.4.10.2.1.6
snmpwalk -v2c -c public <target> LANPLEX-SYSTEMS-MIB-1-2-2::lpsBridgeAddressThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.114.1.4.10.2.1.6.1
snmpget -v2c -c public <target> LANPLEX-SYSTEMS-MIB-1-2-2::lpsBridgeAddressThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.114.1.4.10.2.1.6.1 i <value>

Start monitoring SynOptics/Bay Networks LANplex modular LAN switch with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the LANPLEX-SYSTEMS-MIB-1-2-2::lpsBridgeAddressThreshold OID value, configure state conditions and alerts, and monitor any SynOptics/Bay Networks LANplex modular LAN switch from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.114synerneticsA3Com-products-MIB
1.3.6.1.4.1.114.1lanplexA3Com-products-MIB
1.3.6.1.4.1.114.1.4lanplexSystemsMibA3Com-products-MIB
Numeric OIDNameModule
1.3.6.1.4.1.114.1.4.10lpsBridgeLANPLEX-SYSTEMS-MIB-1-2-2
1.3.6.1.4.1.114.1.4.10.2lpsBridgeTableLANPLEX-SYSTEMS-MIB-1-2-2
1.3.6.1.4.1.114.1.4.10.2.1lpsBridgeEntryLANPLEX-SYSTEMS-MIB-1-2-2
1.3.6.1.4.1.114.1.4.10.2.1.6lpsBridgeAddressThresholdLANPLEX-SYSTEMS-MIB-1-2-2