Juniper-V35-MIB :: juniV35IfClockRate

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › Juniper-V35-MIB › juniV35IfClockRate

juniV35IfClockRate

Module: Juniper-V35-MIB

OID (symbolic): Juniper-V35-MIB::juniV35IfClockRate

OID (numeric): 1.3.6.1.4.1.4874.2.2.59.1.2.1.4

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The clock rate setting in hertz for this X.21/V.35 interface. Only the following values are valid: 1200, 2400, 4800, 9600, 19200, 38400, 56000, 64000, 128000, 1024000, 1536000, 2048000, 3072000, 4096000, 4915200, 6144000, and 8192000. If a value other than one of the predefined values is set, then the closest matching value is used.

The clock rate parameter is only meaningful when the interface is in DCE mode. When the interface is in DTE mode, the value is simply ignored.

What is juniV35IfClockRate?

This read-write Unsigned32, in hertz and defaulting to 2048000, sets the clock rate for a Juniper X.21/V.35 interface, meaningful only when the interface is in DCE mode since the value is ignored in DTE mode. Per the description, only a specific list of standard rates such as 64000, 128000, or 2048000 are valid, and any other value set is rounded to the closest supported rate. For example, an admin configuring a leased line at 2 Mbps would leave juniV35IfClockRate at its default of 2048000 hertz.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.59.1.2.1.4
snmpwalk -v2c -c public <target> Juniper-V35-MIB::juniV35IfClockRate

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.59.1.2.1.4.1
snmpget -v2c -c public <target> Juniper-V35-MIB::juniV35IfClockRate.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4874.2.2.59.1.2.1.4.1 i <value>

Start monitoring Juniper Networks router (X.21/V.35 serial interfaces) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Juniper-V35-MIB::juniV35IfClockRate OID value, configure state conditions and alerts, and monitor any Juniper Networks router (X.21/V.35 serial interfaces) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4874juniperUniJuniper-UNI-SMI
1.3.6.1.4.1.4874.2juniperUniMibsJuniper-UNI-SMI
1.3.6.1.4.1.4874.2.2juniMibsJuniper-MIBs
1.3.6.1.4.1.4874.2.2.59juniV35MIBJuniper-MIBs
Numeric OIDNameModule
1.3.6.1.4.1.4874.2.2.59.1juniV35ObjectsJuniper-V35-MIB
1.3.6.1.4.1.4874.2.2.59.1.2juniV35IfTableJuniper-V35-MIB
1.3.6.1.4.1.4874.2.2.59.1.2.1juniV35IfEntryJuniper-V35-MIB
1.3.6.1.4.1.4874.2.2.59.1.2.1.4juniV35IfClockRateJuniper-V35-MIB