ITOUCHHUB :: concentratorSlotRingSinceZero

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › ITOUCHHUB › concentratorSlotRingSinceZero

concentratorSlotRingSinceZero

Module: ITOUCHHUB

OID (symbolic): ITOUCHHUB::concentratorSlotRingSinceZero

OID (numeric): 1.3.6.1.4.1.33.25.7.1.7

Node type: OBJECT-TYPE

Type: TimeTicks

Access: read-only

Description: This variable reflects the number of time ticks since the counters were last zeroed. This variable is set to zero when concentratoSlotRingZero is written with the value 2

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.33.25.7.1.7
snmpwalk -v2c -c public <target> ITOUCHHUB::concentratorSlotRingSinceZero

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.33.25.7.1.7.1
snmpget -v2c -c public <target> ITOUCHHUB::concentratorSlotRingSinceZero.1

Start monitoring iTouch Communications hub/terminal-server products with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ITOUCHHUB::concentratorSlotRingSinceZero OID value, configure state conditions and alerts, and monitor any iTouch Communications hub/terminal-server products from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.33xyplexCMU-MIB
1.3.6.1.4.1.33.25xConcentratorITOUCH-CONCENTRATOR-MIB
1.3.6.1.4.1.33.25.7concentratorSlotRingTableITOUCH-CONCENTRATOR-MIB
1.3.6.1.4.1.33.25.7.1concentratorSlotRingEntryITOUCH-CONCENTRATOR-MIB
Numeric OIDNameModule
1.3.6.1.4.1.33.25.7.1.7concentratorSlotRingSinceZeroITOUCHHUB