INTELCORPORATIONICMBGENERICCHASSIS-MIB :: a1004ShutdownOsAndPowerOff

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › INTELCORPORATIONICMBGENERICCHASSIS-MIB › a1004ShutdownOsAndPowerOff

a1004ShutdownOsAndPowerOff

Module: INTELCORPORATIONICMBGENERICCHASSIS-MIB

OID (symbolic): INTELCORPORATIONICMBGENERICCHASSIS-MIB::a1004ShutdownOsAndPowerOff

OID (numeric): 1.3.6.1.4.1.343.2.6.2.5.1.1004.1.18

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Writing to this attribute initiates an immediate OS shutdown and Power Off of the system. The value of this attribute is either Do Not Shutdown and Power Off or Shutdown OS and Power Off.

What is a1004ShutdownOsAndPowerOff?

Writing vShutdownAndPowerOff(1) initiates an immediate OS shutdown followed by powering off the system; the alternative is vDoNotShutdownAndPowerOff(0). An admin uses this to remotely take a system fully offline rather than just resetting it.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.343.2.6.2.5.1.1004.1.18
snmpwalk -v2c -c public <target> INTELCORPORATIONICMBGENERICCHASSIS-MIB::a1004ShutdownOsAndPowerOff

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.343.2.6.2.5.1.1004.1.18.1
snmpget -v2c -c public <target> INTELCORPORATIONICMBGENERICCHASSIS-MIB::a1004ShutdownOsAndPowerOff.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.343.2.6.2.5.1.1004.1.18.1 i <value>

Start monitoring Intel-based server chassis implementing ICMB (1990s-era) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INTELCORPORATIONICMBGENERICCHASSIS-MIB::a1004ShutdownOsAndPowerOff OID value, configure state conditions and alerts, and monitor any Intel-based server chassis implementing ICMB (1990s-era) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.343intelAOLAN-MIB
1.3.6.1.4.1.343.2productsAOLAN-MIB
1.3.6.1.4.1.343.2.6snmp_agentsIntel-Common-MIB
1.3.6.1.4.1.343.2.6.2ipConfigurationINTEL-SYS-MIB
1.3.6.1.4.1.343.2.6.2.5broadcastAddressInUseINTEL-SYS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.343.2.6.2.5.1dmtfGroupsINTELCORPORATIONICMBGENERICCHASSIS-MIB
1.3.6.1.4.1.343.2.6.2.5.1.1004tSystemControlINTELCORPORATIONICMBGENERICCHASSIS-MIB
1.3.6.1.4.1.343.2.6.2.5.1.1004.1eSystemControlINTELCORPORATIONICMBGENERICCHASSIS-MIB
1.3.6.1.4.1.343.2.6.2.5.1.1004.1.18a1004ShutdownOsAndPowerOffINTELCORPORATIONICMBGENERICCHASSIS-MIB