INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB :: virtDriveSynchronized

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsINTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIBvirtDriveSynchronized

virtDriveSynchronized

Module: INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB

OID (symbolic): INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB::virtDriveSynchronized

OID (numeric): 1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.8

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: It indicates whether or not the data on the virtual drive has been sychronized.

What is virtDriveSynchronized?

This true/false flag reports whether the data on this virtual drive has been synchronized (its redundant copies/parity are consistent). An admin checks this to confirm a RAID volume has finished its initial sync or rebuild before relying on its redundancy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.8
snmpwalk -v2c -c public <target> INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB::virtDriveSynchronized

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.8.1
snmpget -v2c -c public <target> INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB::virtDriveSynchronized.1

Start monitoring Intel Multi-Flex Server blade chassis (storage module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB::virtDriveSynchronized OID value, configure state conditions and alerts, and monitor any Intel Multi-Flex Server blade chassis (storage module) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.343intelIntel-Common-MIB
1.3.6.1.4.1.343.2productsIntel-Common-MIB
1.3.6.1.4.1.343.2.19modularsystemsINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1multiFlexServerINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1.2componentsINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1.2.10chassisINTELCORPORATION-MULTI-FLEX-SERVER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.343.2.19.1.2.10.208storageINTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB
1.3.6.1.4.1.343.2.19.1.2.10.208.6virtualDriveTableINTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB
1.3.6.1.4.1.343.2.19.1.2.10.208.6.1virtualDriveEntryINTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB
1.3.6.1.4.1.343.2.19.1.2.10.208.6.1.8virtDriveSynchronizedINTELCORPORATION-MULTI-FLEX-SERVER-STORAGE-MIB