pwrSupplyInletTemperature

Module: INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB

OID (symbolic): INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB::pwrSupplyInletTemperature

OID (numeric): 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17

Node type: OBJECT-TYPE

Type: INT32withException

Access: read-only

Description: Power supply Fan blank FRU Inlet Temperature in Degrees Celsius (not applicable to power supplies that do not have an Inlet Temperature

What is pwrSupplyInletTemperature?

The inlet air temperature in degrees Celsius measured at this fan/power FRU, returning notApplicable if the FRU type has no inlet sensor; an admin watches this for early signs of restricted airflow into the chassis.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17
snmpwalk -v2c -c public <target> INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB::pwrSupplyInletTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17.1
snmpget -v2c -c public <target> INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB::pwrSupplyInletTemperature.1

Start monitoring Intel Multi-Flex Server blade chassis (power supply module) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB::pwrSupplyInletTemperature OID value, configure state conditions and alerts, and monitor any Intel Multi-Flex Server blade chassis (power supply module) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.343intelAOLAN-MIB
1.3.6.1.4.1.343.2productsAOLAN-MIB
1.3.6.1.4.1.343.2.19modularsystemsINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1multiFlexServerINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1.2componentsINTELCORPORATION-MULTI-FLEX-SERVER-REG
1.3.6.1.4.1.343.2.19.1.2.10chassisINTELCORPORATION-MULTI-FLEX-SERVER-MIB
Numeric OIDNameModule
1.3.6.1.4.1.343.2.19.1.2.10.207pwrSuppliesINTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
1.3.6.1.4.1.343.2.19.1.2.10.207.1pwrSupplyTableINTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
1.3.6.1.4.1.343.2.19.1.2.10.207.1.1pwrSupplyEntryINTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB
1.3.6.1.4.1.343.2.19.1.2.10.207.1.1.17pwrSupplyInletTemperatureINTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB