-- INTEL CONFIDENTIAL -- Copyright 2006, 2007 -- Intel Corporation All Rights Reserved. -- -- The source code contained or described herein and all documents related to -- the source code ("Material") are owned by Intel Corporation or its -- suppliers and licensors. Title to the Material remains with Intel -- Corporation or its suppliers and licensors. The Material contains trade -- secrets and proprietary and confidential information of Intel or its -- suppliers and licensors. The Material is protected by worldwide copyright -- and trade secret laws and treaty provisions. No part of the Material may be -- used, copied, reproduced, modified, published, uploaded, posted, -- transmitted, distributed, or disclosed in any way without Intel's prior -- express written permission. -- -- Unless otherwise expressly permitted by Intel in a separate license -- agreement, use of the Material is subject to the copyright notices, -- trademarks, warranty, use, and disclosure restrictions reflected on the -- outside of the media, in the documents themselves, and in the "About" or -- "Read Me" or similar file contained within this source code. Unless -- otherwise expressly agreed by Intel in writing, you may not remove -- or alter such notices in any way. -- INTELCORPORATION-MULTI-FLEX-SERVER-PWR-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Integer32, Unsigned32 FROM SNMPv2-SMI OBJECT-GROUP FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC regModule, groups FROM INTELCORPORATION-MULTI-FLEX-SERVER-REG Index, PowerLedStates, FaultLedStates, PresenceLedStates, Presence, Power, INT32withException, IdromBinary16 FROM INTELCORPORATION-MULTI-FLEX-SERVER-TC chassis FROM INTELCORPORATION-MULTI-FLEX-SERVER-MIB; multiFlexServerPwrMibModule MODULE-IDENTITY LAST-UPDATED "200708161330Z" -- August 16, 2007 at 13:30 GMT ORGANIZATION "Intel Corporation" CONTACT-INFO "Brian Kurle Intel Corporation JF5-2-C3 Tel: 503-712-5032 E-Mail: brianx.j.kurle@intel.com" DESCRIPTION "Power Supply Module of the Multi-Flex Server" REVISION "200708161330Z" -- August 16, 2007 at 13:30 GMT DESCRIPTION "Fixed up minor errors causing some managers grief (ommission or addition of commas in lists) Reordered Revision to reverse chronological as some browsers choke, cleaned up some other simple nit-picky errors" REVISION "200707201530Z" -- July 20, 2007 at 15:30 GMT DESCRIPTION "Cleaned up much of the documentation to provide more accurate usage of the individual objects. Particularly, paid attention to the double usage of the pwrSupplyTable where some columns are relevant only if the pwrSupplyType is a power supply, and others only relevant if it is a fan blank." REVISION "200706191130Z" -- June 19, 2007 at 11:30 GMT DESCRIPTION "Finalized the Version information for the MIB based on information available/used by the rest of the system (e.g., the GUI/fwupdate) Dropped pwrSupplyBmcFirmwareVersion. Added pwrSupplyOpCodeVersion & pwrSupplyBootBlockVersion." REVISION "200706072030Z" -- June 07, 2007 at 20:30 GMT DESCRIPTION "Added the IdromBinary16 to represent the asset tag, part number, and serial number fields within the IDROM fields." REVISION "200706071330Z" -- June 07, 2007 at 13:30 GMT DESCRIPTION "Corrected maximum/nominal IDROM parameters and comments" REVISION "200705301900Z" -- May 30, 2007 at 19:00 GMT DESCRIPTION "Introduced the INT32withException type so that enumeration can be managed globally" REVISION "200705221400Z" -- May 22, 2007 at 14:00 GMT DESCRIPTION "Added notApplicable and unknown states to various entries Moved Presence to first column so it's obvious in table display" REVISION "200704271600Z" -- April 27, 2007 at 16:00 GMT DESCRIPTION "Cleaned up the pwrSupplyTable (removed input VDC and corrected column sequencing" REVISION "200704251400Z" -- April 25, 2007 at 14:00 GMT DESCRIPTION "Dropped fanRpmSetting & fanCoefficient from the pwrSupplyFanTable (minor column renumbering). Dropped pwrSupplyNumOfAxis & pwrSupplyFansPerAxis from pwrSupplyTable" REVISION "200704181905Z" -- April 18, 2007 at 19:00 GMT DESCRIPTION "Moved the trees and chassis nodes around to accomodate the unique power supply characteristics. Added the missing numOfPwrUnknowns & pwrSupplyUnknownPresenceMask" REVISION "200704091030Z" -- April 09, 2007 at 10:30 GMT DESCRIPTION "Renamed pwrSupplyFirmwareVersion to pwrSupplyBmcFirmwareVersion to be consistent in naming with other subsystems" REVISION "200704021100Z" -- April 2, 2007 at 11:00 GMT DESCRIPTION "Updated comments to tag fields that may be either statically returned, or that may potentially be removed Added Power supply sensors/status" REVISION "200703131030Z" -- March 13, 2007 at 10:30 GMT DESCRIPTION "pwrSupplyTable data now complies with IDROM (DID/DSD) information. Changed maxPwrSupplies -> maxPwrSupplyFrus Added numOfPwrBlanks & pwrSupplyBlankPresenceMask Added some token information for the expected fan information Renumbered / reorganized accordingly" REVISION "200703061030Z" -- March 06, 2007 at 10:30 GMT DESCRIPTION "Changed Mask representations from an Opaque to a DisplayString at the request of the architects such that it now is an ASCII representation of bit string reflecting the presence with the left most 'bit' being bit 1 and max* bits being represented." REVISION "200702221700Z" -- February 22, 2007 at 17:00 GMT DESCRIPTION "Renamed MIB file and updated internal relevance to formal product name Multi-Flex Server" REVISION "200611070701Z" -- November 07, 2006 at 07:01 GMT DESCRIPTION "Consolodated use of Presence datatype and changed 'chassis' to 'chassis'" REVISION "200609291529Z" -- September 29, 2006 at 15:29 GMT DESCRIPTION "Partitioned off and created as it's own module" ::= { regModule 17 } -- ---------------------------------------------------------------------------- -- -- Power Supply group. -- -- This group contains information about Power Supply. -- -- ---------------------------------------------------------------------------- -- -- Power Supply relevant pieces stored in the chassis -- maxPwrSupplies OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum number of Power Supply FRUs (including Power Supply Blanks and unknown) possible in this chassis." ::= { chassis 17 } numOfPwrSupplies OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Power Supplies (excludes blanks & unknown Frus in power supply slots)." ::= { chassis 27 } numOfPwrBlanks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of Power Supply Blanks (Fan only) in the system." ::= { chassis 28 } numOfPwrUnknowns OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of FRUs occupying power supply slots that are neither recognized as power supplies, nor blanks." ::= { chassis 29 } pwrSupplyPresenceMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII representation of bit string reflecting the presence of a recognized power supply in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes fan blanks and unrecognized FRUs. Thus, '0101' would express that power supply FRUs 2 & 4 are recognized power supplies present" ::= { chassis 37 } pwrSupplyBlankPresenceMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII representation of bit string reflecting the presence of a recognized fan blanks in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes both recognized and unrecognized power supplies. Thus, '0010' would express that power supply FRU 3 is a recognized fan blank present" ::= { chassis 38 } pwrSupplyUnknownPresenceMask OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "ASCII representation of bit string reflecting the presence of a unrecognized FRUs in the power supply slots with the left most 'bit' being bit 1 and maxPwrSupplies bits being represented. This excludes recognized power supplies and fan blanks. Thus, '1000' would express that an unrecognized FRU is in the power supply slot 1 is present" ::= { chassis 39 } -- -- Power Supply Tree -- pwrSupplies OBJECT-IDENTITY STATUS current DESCRIPTION "Container for Power Supply specific information as well as all components logically contained within." ::= { chassis 207 } pwrSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF PwrSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row describes a Power Supply FRU in the chassis" ::= { pwrSupplies 1 } pwrSupplyEntry OBJECT-TYPE SYNTAX PwrSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION ".." INDEX { pwrSupplyIndex } ::= { pwrSupplyTable 1 } PwrSupplyEntry ::= SEQUENCE { pwrSupplyIndex Index, pwrSupplyPresence Presence, pwrSupplyVendor DisplayString, pwrSupplyMfgDate DisplayString, pwrSupplyDeviceName DisplayString, pwrSupplyPart IdromBinary16, pwrSupplySerialNo IdromBinary16, pwrSupplyMaximumPower Power, pwrSupplyNominalPower Power, pwrSupplyAssetTag IdromBinary16, pwrSupplyPowerLed PowerLedStates, pwrSupplyFaultLed FaultLedStates, pwrSupplyOpCodeVersion DisplayString, pwrSupplyBootBlockVersion DisplayString, pwrSupplyType INTEGER, pwrSupplyNumOfFans INT32withException, pwrSupplyInletTemperature INT32withException, pwrSupplyOutputVdc INT32withException, pwrSupplyOutputAmp INT32withException, pwrSupplyOutputPickAmp INT32withException, pwrSupplyHotspotTemp INT32withException, pwrSupplyEmbTemp INT32withException, pwrSupplyStatus BITS } pwrSupplyIndex OBJECT-TYPE SYNTAX Index MAX-ACCESS read-only STATUS current DESCRIPTION "column used to identify a particular Power Supply." ::= { pwrSupplyEntry 1 } pwrSupplyPresence OBJECT-TYPE SYNTAX Presence MAX-ACCESS read-only STATUS current DESCRIPTION "Flag whether something is occupying the the power supply slot (being either a power supply, a power supply blank, or unknown device) pwrSupplyType within this row should be consulted to determine what is occupying the slot." ::= { pwrSupplyEntry 2 } pwrSupplyVendor OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device manufacturer" ::= { pwrSupplyEntry 3 } pwrSupplyMfgDate OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Manufacture date/time" ::= { pwrSupplyEntry 4 } pwrSupplyDeviceName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Device Name" ::= { pwrSupplyEntry 5 } pwrSupplyPart OBJECT-TYPE SYNTAX IdromBinary16 MAX-ACCESS read-only STATUS current DESCRIPTION "Device Part Number" ::= { pwrSupplyEntry 6 } pwrSupplySerialNo OBJECT-TYPE SYNTAX IdromBinary16 MAX-ACCESS read-only STATUS current DESCRIPTION "Device Serial Number" ::= { pwrSupplyEntry 7 } pwrSupplyMaximumPower OBJECT-TYPE SYNTAX Power MAX-ACCESS read-only STATUS current DESCRIPTION "Static maximum power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Maximum power generation/consumption not known or specified" ::= { pwrSupplyEntry 8 } pwrSupplyNominalPower OBJECT-TYPE SYNTAX Power MAX-ACCESS read-only STATUS current DESCRIPTION "Static Nominal power generation / consumption (in watts): <0 - Negative numbers indicate device consumes power (in watts) >0 - Positive numbers indicate device generates power (in watts) 0 - Device is passive (does not not consume or generate power) -1 - Nominal power generation/consumption not known or specified" ::= { pwrSupplyEntry 9 } pwrSupplyAssetTag OBJECT-TYPE SYNTAX IdromBinary16 MAX-ACCESS read-only STATUS current DESCRIPTION "Asset Tag # of device" ::= { pwrSupplyEntry 10 } pwrSupplyPowerLed OBJECT-TYPE SYNTAX PowerLedStates MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Power LED on the Power Supply" ::= { pwrSupplyEntry 11 } pwrSupplyFaultLed OBJECT-TYPE SYNTAX FaultLedStates MAX-ACCESS read-only STATUS current DESCRIPTION "State of the Fault LED on the Power Supply (and optionally intiate identification)" ::= { pwrSupplyEntry 12 } pwrSupplyOpCodeVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BMC Firmware version on the Fan Blank (only)" ::= { pwrSupplyEntry 13 } pwrSupplyBootBlockVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "BMC Firmware version on the Fan Blank (only)" ::= { pwrSupplyEntry 14 } pwrSupplyType OBJECT-TYPE SYNTAX INTEGER { notApplicable(-32), unknown(-16), powerSuppy(1), powerSupplyBank(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Enumeration telling what kind of power supply FRU is in the slot" ::= { pwrSupplyEntry 15 } pwrSupplyNumOfFans OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Number of Fans contained within this FRU May be static data given the FRU" ::= { pwrSupplyEntry 16 } pwrSupplyInletTemperature OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply Fan blank FRU Inlet Temperature in Degrees Celsius (not applicable to power supplies that do not have an Inlet Temperature" ::= { pwrSupplyEntry 17 } -- -- Power supply sensors -- pwrSupplyOutputVdc OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's output voltage in millivolts notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown" ::= { pwrSupplyEntry 18 } pwrSupplyOutputAmp OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's output amperage in milliamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown" ::= { pwrSupplyEntry 19 } pwrSupplyOutputPickAmp OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's output pick amperage in milliiamps notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown" ::= { pwrSupplyEntry 20 } pwrSupplyHotspotTemp OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's Hotspot Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown" ::= { pwrSupplyEntry 21 } pwrSupplyEmbTemp OBJECT-TYPE SYNTAX INT32withException MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's EMB Temperature in degrees Celsius degrees Celsius - when power supply is present notApplicable - if a power supply fan blank, or isn't present unknown - if device type is unknown" ::= { pwrSupplyEntry 22 } pwrSupplyStatus OBJECT-TYPE SYNTAX BITS { unused1(0), unused2(1), powerSupplyOn(2), powerOK(3), unused(4), overTemp(5), overCurrent(6), supplyFault(7) } MAX-ACCESS read-only STATUS current DESCRIPTION "Power supply's status bits (power supply only) This is used to provide multiple enumerations (by bits) of the status. E.g., powerSupplyOn(2) powerOK(3). " ::= { pwrSupplyEntry 23 } -- -- Individual Fans within a power supply or power supply blank -- pwrSupplyFanTable OBJECT-TYPE SYNTAX SEQUENCE OF PwrSupplyFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Each row describes a Fan in a Fan FRU (indexed by the Fan FRU and by individual Fan) Current, this should include the 3 Fan FRUs (the two system Fan FRUs and the I/O Fan FRU) The number of Fans is dependent upon the FRU (see pwrSupplyFanFruNumOfFans in the fanFruTable for a particular FRU)" ::= { pwrSupplies 2 } pwrSupplyFanEntry OBJECT-TYPE SYNTAX PwrSupplyFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION ".." INDEX { pwrSupplyIndex, pwrSupplyFanIndex } ::= { pwrSupplyFanTable 1 } PwrSupplyFanEntry ::= SEQUENCE { pwrSupplyFanIndex Index, pwrSupplyFanRpmMinimum Integer32, pwrSupplyFanRpmMaximum Integer32, pwrSupplyFanRpmReading INTEGER } pwrSupplyFanIndex OBJECT-TYPE SYNTAX Index MAX-ACCESS read-only STATUS current DESCRIPTION "which pwrSupplyFan within a FRU we're talking about" ::= { pwrSupplyFanEntry 1 } pwrSupplyFanRpmMinimum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Minimum settable RPM Potentially to be removed - See Murali/Niel" ::= { pwrSupplyFanEntry 2 } pwrSupplyFanRpmMaximum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Maximum settable RPM Potentially to be removed - See Murali/Niel" ::= { pwrSupplyFanEntry 3 } pwrSupplyFanRpmReading OBJECT-TYPE SYNTAX INTEGER { notApplicable(-32), unknown(-16), notspinning (0) } MAX-ACCESS read-only STATUS current DESCRIPTION "Fan's current RPM reading: 0 - Fan not spinning unknown - Indeterminate data (no communications, or unknown device present) notApplicable - Not present" ::= { pwrSupplyFanEntry 4 } -- -- (Power Supply) Group information -- pwrSupplyGroup OBJECT-GROUP OBJECTS { maxPwrSupplies, numOfPwrSupplies, numOfPwrBlanks, numOfPwrUnknowns, pwrSupplyPresenceMask, pwrSupplyBlankPresenceMask, pwrSupplyUnknownPresenceMask, pwrSupplyIndex, pwrSupplyVendor, pwrSupplyMfgDate, pwrSupplyDeviceName, pwrSupplyPart, pwrSupplySerialNo, pwrSupplyMaximumPower, pwrSupplyNominalPower, pwrSupplyAssetTag, pwrSupplyPowerLed, pwrSupplyFaultLed, pwrSupplyOpCodeVersion, pwrSupplyBootBlockVersion, pwrSupplyPresence, pwrSupplyType, pwrSupplyNumOfFans, pwrSupplyInletTemperature, pwrSupplyOutputVdc, pwrSupplyOutputAmp, pwrSupplyOutputPickAmp, pwrSupplyHotspotTemp, pwrSupplyEmbTemp, pwrSupplyStatus, pwrSupplyFanIndex, pwrSupplyFanRpmMinimum, pwrSupplyFanRpmMaximum, pwrSupplyFanRpmReading } STATUS current DESCRIPTION "Description." ::= { groups 17 } END -- vim:ts=4:ai:nohls:nowrap:expandtab