INCOGNITO-EXPR-IPCOMMANDER-MIB :: ipcFailStatSendErrors

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › INCOGNITO-EXPR-IPCOMMANDER-MIB › ipcFailStatSendErrors

ipcFailStatSendErrors

Module: INCOGNITO-EXPR-IPCOMMANDER-MIB

OID (symbolic): INCOGNITO-EXPR-IPCOMMANDER-MIB::ipcFailStatSendErrors

OID (numeric): 1.3.6.1.4.1.3606.7.1.2.100.1.1.2.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of errors that have occurred sending failover messages since the last time this counter was reset.

What is ipcFailStatSendErrors?

Running count of errors sending failover protocol messages to the partner DHCP service since the counter was last reset; a rising count points to network or partner-service problems.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3606.7.1.2.100.1.1.2.1
snmpwalk -v2c -c public <target> INCOGNITO-EXPR-IPCOMMANDER-MIB::ipcFailStatSendErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3606.7.1.2.100.1.1.2.1.1
snmpget -v2c -c public <target> INCOGNITO-EXPR-IPCOMMANDER-MIB::ipcFailStatSendErrors.1

Start monitoring Incognito Software Express IP Commander DHCP/DNS/IPAM server with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the INCOGNITO-EXPR-IPCOMMANDER-MIB::ipcFailStatSendErrors OID value, configure state conditions and alerts, and monitor any Incognito Software Express IP Commander DHCP/DNS/IPAM server from a single console.

How to Use in IPNetwork Monitor

Select an Incognito Software Express IP Commander DHCP/DNS/IPAM server as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ipcFailStatSendErrors into the Find box to locate it in the OID tree, then select it and click OK. The number of errors that have occurred sending failover messages since the last time this counter was reset. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3606incognitoINCOGNITO-MIB
1.3.6.1.4.1.3606.7incognitoExprINCOGNITO-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3606.7.1incognitoIPCINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2ipcServerObjectsINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2.100ipcFailoverINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2.100.1ipcFailoverStatisticsINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2.100.1.1ipcFailoverSummaryStatisticsINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2.100.1.1.2ipcFailoverErrorSummaryStatisticsINCOGNITO-EXPR-IPCOMMANDER-MIB
1.3.6.1.4.1.3606.7.1.2.100.1.1.2.1ipcFailStatSendErrorsINCOGNITO-EXPR-IPCOMMANDER-MIB