IEEE-802DOT17-RPR-MIB :: rprIfIdleThreshold

MIB Reference — IPNetwork Monitor

All MIBsIEEE-802DOT17-RPR-MIBrprIfIdleThreshold

rprIfIdleThreshold

Module: IEEE-802DOT17-RPR-MIB

OID (symbolic): IEEE-802DOT17-RPR-MIB::rprIfIdleThreshold

OID (numeric): 1.0.8802.17.1.1.1.1.1.1.13

Node type: OBJECT-TYPE

Type: Gauge

Access: read-write

Description:

Indicates that a MAC is experiencing an adverse rate mismatch. When the PTQ depth exceeds this value, the incoming link is considered adversely rate mismatched.

This attribute specifies the idle-threshold location from the top of the PTQ buffer, in MTU size.

Default value should be 1, which means (sizePTQ - mtuSize)

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.0.8802.17.1.1.1.1.1.1.13
snmpwalk -v2c -c public <target> IEEE-802DOT17-RPR-MIB::rprIfIdleThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.0.8802.17.1.1.1.1.1.1.13.1
snmpget -v2c -c public <target> IEEE-802DOT17-RPR-MIB::rprIfIdleThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.0.8802.17.1.1.1.1.1.1.13.1 i <value>

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.0stdSTART-MIB
1.0.8802iso8802START-MIB
1.0.8802.17.1.1ieee802dot17rprMIBIEEE-802DOT17-RPR-MIB
1.0.8802.17.1.1.1rprObjectsIEEE-802DOT17-RPR-MIB
1.0.8802.17.1.1.1.1rprGeneralIEEE-802DOT17-RPR-MIB
1.0.8802.17.1.1.1.1.1rprIfTableIEEE-802DOT17-RPR-MIB
1.0.8802.17.1.1.1.1.1.1rprIfEntryIEEE-802DOT17-RPR-MIB
1.0.8802.17.1.1.1.1.1.1.13rprIfIdleThresholdIEEE-802DOT17-RPR-MIB