IBM-SYSTEM-POWER-MIB :: ibmSystemPowerSupplyEventAutoClearEnabled

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › IBM-SYSTEM-POWER-MIB › ibmSystemPowerSupplyEventAutoClearEnabled

ibmSystemPowerSupplyEventAutoClearEnabled

Module: IBM-SYSTEM-POWER-MIB

OID (symbolic): IBM-SYSTEM-POWER-MIB::ibmSystemPowerSupplyEventAutoClearEnabled

OID (numeric): 1.3.6.1.4.1.2.6.159.1.1.130.1.1.8

Node type: OBJECT-TYPE

Type: Boolean

Access: read-only

Description: Status stating if power supply events are configured to automatically clear. [True | False]

What is ibmSystemPowerSupplyEventAutoClearEnabled?

This value reports whether power supply events are configured to automatically clear once the underlying condition resolves. Admins check it to know whether a resolved power supply fault will disappear from the event log on its own or require manual acknowledgment. A returned value of true means an event raised for this power supply will clear itself automatically once the fault condition is no longer present.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2.6.159.1.1.130.1.1.8
snmpwalk -v2c -c public <target> IBM-SYSTEM-POWER-MIB::ibmSystemPowerSupplyEventAutoClearEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2.6.159.1.1.130.1.1.8.1
snmpget -v2c -c public <target> IBM-SYSTEM-POWER-MIB::ibmSystemPowerSupplyEventAutoClearEnabled.1

Start monitoring IBM system with CIM-instrumented power supply with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the IBM-SYSTEM-POWER-MIB::ibmSystemPowerSupplyEventAutoClearEnabled OID value, configure state conditions and alerts, and monitor any IBM system with CIM-instrumented power supply from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2ibmATM-ADAPTER-MIB
1.3.6.1.4.1.2.6ibmProdATM-ADAPTER-MIB
1.3.6.1.4.1.2.6.159directorIBM-Director-Agent-MIB
1.3.6.1.4.1.2.6.159.1ibmSystemIBM-SYSTEM-MIB
1.3.6.1.4.1.2.6.159.1.1ibmSystemMIBIBM-SYSTEM-MIB
1.3.6.1.4.1.2.6.159.1.1.130ibmSystemPowerIBM-SYSTEM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2.6.159.1.1.130.1ibmSystemPowerSupplyTableIBM-SYSTEM-POWER-MIB
1.3.6.1.4.1.2.6.159.1.1.130.1.1ibmSystemPowerSupplyEntryIBM-SYSTEM-POWER-MIB
1.3.6.1.4.1.2.6.159.1.1.130.1.1.8ibmSystemPowerSupplyEventAutoClearEnabledIBM-SYSTEM-POWER-MIB