HUAWEI-ENERGYMNGT-MIB :: hwPowerConsumption

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-ENERGYMNGT-MIB › hwPowerConsumption

hwPowerConsumption

Module: HUAWEI-ENERGYMNGT-MIB

OID (symbolic): HUAWEI-ENERGYMNGT-MIB::hwPowerConsumption

OID (numeric): 1.3.6.1.4.1.2011.6.157.1.1

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: NE total power consumption, counted from equipment first used. Joule(Watt * second). Note: If the device is a power supplier(PSE), the power consumption includes the outputs.

What is hwPowerConsumption?

The device's cumulative total energy consumed since it was first put into service, measured in joules (watt-seconds); for a PSE, this figure includes the power delivered to connected PoE devices.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.157.1.1
snmpwalk -v2c -c public <target> HUAWEI-ENERGYMNGT-MIB::hwPowerConsumption

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.157.1.1.1
snmpget -v2c -c public <target> HUAWEI-ENERGYMNGT-MIB::hwPowerConsumption.1

Start monitoring Huawei router or switch (power consumption/energy-saving policy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-ENERGYMNGT-MIB::hwPowerConsumption OID value, configure state conditions and alerts, and monitor any Huawei router or switch (power consumption/energy-saving policy) from a single console.

How to Use in IPNetwork Monitor

Select a Huawei router or switch (power consumption/energy-saving policy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hwPowerConsumption into the Find box to locate it in the OID tree, then select it and click OK. It reports nE total power consumption, counted from equipment first used. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.157hwEnergyMngtHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.1hwSysPowerMgntHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.1.1hwPowerConsumptionHUAWEI-ENERGYMNGT-MIB