HUAWEI-ENERGYMNGT-MIB :: hwEnergyFtpOperStatus

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HUAWEI-ENERGYMNGT-MIB › hwEnergyFtpOperStatus

hwEnergyFtpOperStatus

Module: HUAWEI-ENERGYMNGT-MIB

OID (symbolic): HUAWEI-ENERGYMNGT-MIB::hwEnergyFtpOperStatus

OID (numeric): 1.3.6.1.4.1.2011.6.157.4.1.1.15

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The OperStatus: opInProgress(1): the operation is in process. opSuccess(2): the operation has been completed successfully. opInvalid(3): the command is invalid or command-protocol-device combination is unsupported by the system. opInvalidProtocol(4): invalid protocol is specified opInvalidSourceName(5) :invalid source file name is specified. opInvalidDestName(6): invalid target name is specified. opInvalidServerAddress(7): invalid server address is specified opDeviceBusy(8): the device is in use and locked by another process opDeviceError(9): device read, write or erase error opFileOpenError(10) :invalid file name; file not found in partition opFileTransferError(11) :file transfer was unsuccessfull opFileChecksumError(12) :file checksum in Flash is invalid opAuthFail(13) :authentication failure opUnknownFailure(14) :failure which is unknown opAbort(15) : transfer operation has been aborted opInvalidSourceAddress(16): invalid source IP is specified. opInvalidSourceInterface(17): invalid source interface is specified.

What is hwEnergyFtpOperStatus?

Reports the outcome of the most recent FTP/SFTP/TFTP transfer used to fetch or push an energy-saving capability file, ranging from opInProgress and opSuccess to specific failure codes like opAuthFail or opFileTransferError.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2011.6.157.4.1.1.15
snmpwalk -v2c -c public <target> HUAWEI-ENERGYMNGT-MIB::hwEnergyFtpOperStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2011.6.157.4.1.1.15.1
snmpget -v2c -c public <target> HUAWEI-ENERGYMNGT-MIB::hwEnergyFtpOperStatus.1

Start monitoring Huawei router or switch (power consumption/energy-saving policy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HUAWEI-ENERGYMNGT-MIB::hwEnergyFtpOperStatus OID value, configure state conditions and alerts, and monitor any Huawei router or switch (power consumption/energy-saving policy) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.2011huaweiEXPERTV2-MIB
1.3.6.1.4.1.2011.6huaweiUtilityHUAWEI-3COM-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2011.6.157hwEnergyMngtHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.4hwEnergyFtpcObjectsHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.4.1hwEnergyFtpcTransFileTableHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.4.1.1hwEnergyFtpcTransFileEntryHUAWEI-ENERGYMNGT-MIB
1.3.6.1.4.1.2011.6.157.4.1.1.15hwEnergyFtpOperStatusHUAWEI-ENERGYMNGT-MIB