All MIBs › HPN-ICF-POWER-ETH-EXT-MIB › hpnicfPOEThresholdDCMaximum
hpnicfPOEThresholdDCMaximum
Module: HPN-ICF-POWER-ETH-EXT-MIB
OID (symbolic): HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdDCMaximum
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.4
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: Input threshold DC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 57.0V and larger than 55.0V.
What is hpnicfPOEThresholdDCMaximum?
This read-write value is a numeric string (terminated by a null character, digits and at most one decimal point) that sets the high DC output voltage alarm threshold, constrained between 55.0V and 57.0V. An admin uses this to catch an over-voltage DC rail condition that could damage connected PoE devices.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.4 snmpwalk -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdDCMaximum
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.4.1 snmpget -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdDCMaximum.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.4.1 s <value>
Start monitoring HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdDCMaximum OID value, configure state conditions and alerts, and monitor any HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14 | hpnicfPowerEthernetExt | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8 | hpnicfPOEPowerObjects | HPN-ICF-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1 | hpnicfPOEThresholdLimitObjs | HPN-ICF-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.4 | hpnicfPOEThresholdDCMaximum | HPN-ICF-POWER-ETH-EXT-MIB |