All MIBs › HPN-ICF-POWER-ETH-EXT-MIB › hpnicfPOEThresholdACMimimum
hpnicfPOEThresholdACMimimum
Module: HPN-ICF-POWER-ETH-EXT-MIB
OID (symbolic): HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMimimum
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.1
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the hpnicfPOEThresholdACMaximum.
What is hpnicfPOEThresholdACMimimum?
This read-write value is a numeric string (terminated by a null character, digits and at most one decimal point) that sets the low AC input voltage alarm threshold, constrained between 90.0V and 264.0V and required to stay below hpnicfPOEThresholdACMaximum. An admin lowers this to reduce false alarms on a site with a known 'brownout' pattern, while keeping it above the true minimum operating voltage of the PoE supply.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.1 snmpwalk -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMimimum
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.1.1 snmpget -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMimimum.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.1.1 s <value>
Start monitoring HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMimimum OID value, configure state conditions and alerts, and monitor any HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14 | hpnicfPowerEthernetExt | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8 | hpnicfPOEPowerObjects | HPN-ICF-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1 | hpnicfPOEThresholdLimitObjs | HPN-ICF-POWER-ETH-EXT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.1 | hpnicfPOEThresholdACMimimum | HPN-ICF-POWER-ETH-EXT-MIB |