hpnicfPOEThresholdACMaximum

Module: HPN-ICF-POWER-ETH-EXT-MIB

OID (symbolic): HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMaximum

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: Input threshold AC maximum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. It should be smaller than 264.0V and larger than 90.0V. And it should be larger than the hpnicfPOEThresholdACMinimum.

What is hpnicfPOEThresholdACMaximum?

This read-write value is a numeric string (terminated by a null character, digits and at most one decimal point) that sets the high AC input voltage alarm threshold, constrained between 90.0V and 264.0V and required to stay above hpnicfPOEThresholdACMinimum. An admin sets this near the supply's rated ceiling so an over-voltage alarm fires before equipment is damaged.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.2
snmpwalk -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMaximum

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.2.1
snmpget -v2c -c public <target> HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMaximum.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.2.1 s <value>

Start monitoring HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-POWER-ETH-EXT-MIB::hpnicfPOEThresholdACMaximum OID value, configure state conditions and alerts, and monitor any HP/H3C Comware-based Ethernet switch with PoE ports (extended power-budget/class) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.14hpnicfPowerEthernetExtHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.14.8hpnicfPOEPowerObjectsHPN-ICF-POWER-ETH-EXT-MIB
1.3.6.1.4.1.11.2.14.11.15.2.14.8.1hpnicfPOEThresholdLimitObjsHPN-ICF-POWER-ETH-EXT-MIB
1.3.6.1.4.1.11.2.14.11.15.2.14.8.1.2hpnicfPOEThresholdACMaximumHPN-ICF-POWER-ETH-EXT-MIB