Description: This object returns the current state of traffic redirection to the cache.
If redirection is disabled, this object shall return disabledNotRedirecting(1).
If a unit cannot be selected to perform the cache health check, this object shall return enabledNoHealthChecker(2).
If the software is determining if the cache is able to do redirection(this will happen when the redirection state transitions from disabled to enabled), this object shall return enabledHealthChecking(3).
If the cache health check succeeded but the hardware is unable to support redirection to the cache port, this object shall return enabledHealthCheckOKNotRedirecting(4).
If the latest health check of the cache has failed, this object shall return enabledHealthCheckFailed(5).
If the cache is in use and traffic is being redirected to it, this object shall return enabledRedirecting(6).
The default value is disabledNotRedirecting(1).
What is hpnicfL4RedirectCacheRedirectionStatus?
hpnicfL4RedirectCacheRedirectionStatus reports the current state of Layer 4 traffic redirection to a configured web cache device, ranging from disabledNotRedirecting when redirection is off to enabledRedirecting when traffic is actively being sent to the cache, with intermediate states covering health-check progress and failures. An admin uses it to diagnose why traffic isn't reaching a cache device, distinguishing a disabled configuration from a cache that failed its health check. For example, seeing hpnicfL4RedirectCacheRedirectionStatus return enabledHealthCheckFailed tells the admin the cache is configured and enabled but currently failing its health probes, so traffic isn't being redirected.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.10.1.1.2 snmpwalk -v2c -c public <target> HPN-ICF-L4RDT-MIB::hpnicfL4RedirectCacheRedirectionStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.10.1.1.2.1 snmpget -v2c -c public <target> HPN-ICF-L4RDT-MIB::hpnicfL4RedirectCacheRedirectionStatus.1
Start monitoring H3C/HPE Networking (ICF-based) device (Layer 4 Redirect/captive portal) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-L4RDT-MIB::hpnicfL4RedirectCacheRedirectionStatus OID value, configure state conditions and alerts, and monitor any H3C/HPE Networking (ICF-based) device (Layer 4 Redirect/captive portal) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.10 | hpnicfL4Redirect | HPN-ICF-L4RDT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.10.1 | hpnicfL4RedirectCacheTable | HPN-ICF-L4RDT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.10.1.1 | hpnicfL4RedirectCacheEntry | HPN-ICF-L4RDT-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.10.1.1.2 | hpnicfL4RedirectCacheRedirectionStatus | HPN-ICF-L4RDT-MIB |