HPN-ICF-IFQOS2-MIB :: hpnicfIfQoSWredDropPPS

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HPN-ICF-IFQOS2-MIB › hpnicfIfQoSWredDropPPS

hpnicfIfQoSWredDropPPS

Module: HPN-ICF-IFQOS2-MIB

OID (symbolic): HPN-ICF-IFQOS2-MIB::hpnicfIfQoSWredDropPPS

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1.1.19

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-only

Description: The PPS of packets dropped by WRED.

What is hpnicfIfQoSWredDropPPS?

The current rate, in packets per second, at which WRED is dropping packets from this queue; admins use it to confirm WRED is actively doing its congestion-avoidance job during a busy period rather than the queue just quietly tail-dropping.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1.1.19
snmpwalk -v2c -c public <target> HPN-ICF-IFQOS2-MIB::hpnicfIfQoSWredDropPPS

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1.1.19.1
snmpget -v2c -c public <target> HPN-ICF-IFQOS2-MIB::hpnicfIfQoSWredDropPPS.1

Start monitoring HPE/H3C Comware switch or router (per-interface QoS/shaping/policing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-IFQOS2-MIB::hpnicfIfQoSWredDropPPS OID value, configure state conditions and alerts, and monitor any HPE/H3C Comware switch or router (per-interface QoS/shaping/policing) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.65hpnicfQos2HPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1hpnicfIfQos2HPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1.1hpnicfIfQoSHardwareQueueObjectsHPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2hpnicfIfQoSHardwareQueueRunInfoGroupHPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1hpnicfIfQoSHardwareQueueRunInfoTableHPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1.1hpnicfIfQoSHardwareQueueRunInfoEntryHPN-ICF-IFQOS2-MIB
1.3.6.1.4.1.11.2.14.11.15.2.65.1.1.2.1.1.19hpnicfIfQoSWredDropPPSHPN-ICF-IFQOS2-MIB