Start monitoring vendor-neutral, standards-based MIB, any SNMPv3-capable network device (SNMP engine identity/boot/clock status) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.
What Is HPN-ICF-HGMP-MIB?
This MIB manages the HP Group Management Protocol (HGMP), a proprietary HP/H3C protocol used for cluster-based management of multiple LAN switches through a single management IP address. It belongs to the HP/Comware "lanswitch" family and exposes configuration and status data for organizing switches into administrative clusters, electing a management device, and tracking member devices. Though no sample objects were provided, HGMP MIBs of this kind typically expose cluster membership status, member device reachability/uptime, and role (management device vs. member), giving visibility into whether the switch cluster's software-level control plane is healthy. It is a vendor-proprietary HP/H3C mechanism with no direct dependency on IETF standard cluster-management MIBs. It is typically deployed across stacks of HP/Comware access-layer LAN switches managed collectively as a single logical unit. Network engineers evaluating or troubleshooting this functionality can download the HPN-ICF-HGMP-MIB file directly to load it into their MIB browser.
IPNetwork Monitor allows you to monitor SNMP objects defined in HPN-ICF-HGMP-MIB. Use the built-in SNMP Monitoring Browser to explore available variables, view their current values and descriptions, and select the objects you want to monitor. You can then create SNMP monitors, configure thresholds, and receive alerts when monitored values change.
Supported Devices
- HP/H3C Comware LAN switch (clustered)
Monitoring Examples
No sample objects were provided for this MIB, and the module description gives only a high-level statement that it manages "hpnicfhgmp operations" on lanswitch products, so a concrete object-level monitoring scenario cannot be honestly constructed from the available information.
This MIB depends on
Related MIBs
Imported Objects
From HPN-ICF-OID-MIB
| hpnicfRhw | OBJECT-IDENTITY |
From SNMPv2-SMI
| Counter32 | |
| Integer32 | |
| IpAddress | |
| MODULE-IDENTITY | |
| NOTIFICATION-TYPE | |
| OBJECT-IDENTITY | |
| OBJECT-TYPE | |
| Unsigned32 |
From SNMPv2-TC
| DisplayString | |
| MacAddress | |
| RowStatus | |
| TEXTUAL-CONVENTION |
OIDs
| OID symbolic | OID numeric | Type | Access | Description |
|---|---|---|---|---|
| hpnicfHgmp | 1.3.6.1.4.1.11.2.14.11.15.8.7 | This MIB contains objects to manage the hpnicfhgmp operations, which are used on lanswitch products. | ||
| hpnicfClusterObject | 1.3.6.1.4.1.11.2.14.11.15.8.7.1 | This MIB contains objects to manage the cluster operations, which are used on lanswitch products. | ||
| hpnicfhgmpEventsV2 | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.0 | Definition point for cluster notifications. | ||
| NTF hpnicfhgmpMemberfailure | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.0.1 | When a cluster member failure, send a snmp trap to the network management. | ||
| NTF hpnicfhgmpMemberRecover | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.0.2 | When a cluster member recover, send a snmp trap to the network management. | ||
| NTF hpnicfhgmpMemberStatusChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.0.3 | When a cluster member status change, send a snmp trap to the network management. | ||
| NTF hpnicfhgmpNetTopChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.0.4 | When net topology of this cluster change, send a snmp trap to the network management. | ||
| INT hpnicfhgmpSetVLANSecurity | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.1 | INTEGER | read-write | Configure whether to perform the VLAN check inside the cluster. |
| I32 hpnicfhgmpHandShakeInterval | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.2 | Integer32 | read-write | Handshaking interval of the cluster member switches. |
| I32 hpnicfhgmpHandShakeHoldtime | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.3 | Integer32 | read-write | Holdtime of administrator switch and member switch in the cluster. |
| I32 hpnicfhgmpGrpMemberTableChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.4 | Integer32 | read-only | Add 1 to the member list after it changes. The administrator checks if the value has changed. If not, he will not read the list once more. |
| I32 hpnicfhgmpMemberDisconRate | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.5 | Integer32 | read-only | Disconnection times of the member and administrator switches divided by member number times 1000. |
| INT hpnicfhgmpCmdLanswitchFlag | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.6 | INTEGER | read-write | Administrator switch flag |
| OCT hpnicfhgmpCmdClusterName | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.7 | OCTET STRING | read-write | Cluster name of the administrator switch |
| IP hpnicfhgmpMngPriIpSegCMIP | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.8 | IpAddress | read-write | The private management IP address of the administrator switch, which can not be modified after the cluster has been created. |
| IP hpnicfhgmpMngPriIpMask | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.9 | IpAddress | read-write | The private management IP address mask assigned by the administrator switch, which cannot be modified after the cluster has been created. |
| IP hpnicfhgmpFtpServer | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.10 | IpAddress | read-write | The cluster members can access the Ftp Server through the administrator switch, which can only be configured and accessed on the administrator switch. |
| IP hpnicfhgmpTftpServer | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.11 | IpAddress | read-write | The cluster members can access the Tftp Server through the administrator switch, which can only be configured and accessed on the administrator switch. |
| IP hpnicfhgmpSnmpHost | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.12 | IpAddress | read-write | The Snmp Host to send the cluster trap packets, which can only be configured and accessed on the administrator switch. |
| IP hpnicfhgmpLogHost | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.13 | IpAddress | read-write | Log host of the cluster, which can only be configured and accessed on the administrator switch. |
| hpnicfhgmpGrpMemberTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14 | not-accessible | Table of cluster member switches | |
| hpnicfhgmpGrpMemberEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1 | not-accessible | ||
| OCT hpnicfhgmpGrpMemberDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.1 | OCTET STRING | read-only | 4 bytes reserved as 0x0 + 6 bytes of MAC address, expressed as a character string of the hexadecimal number. |
| I32 hpnicfhgmpGrpMemberSerial | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.2 | Integer32 | read-only | When adding member switch to the cluster, the administrator switch will assign an unique integer to identify it. |
| IP hpnicfhgmpGrpMemberIpAddr | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.3 | IpAddress | read-only | The private IP addresses of the member switches for the communication inside the cluster. |
| OCT hpnicfhgmpGrpMemberName | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.4 | OCTET STRING | read-only | Hostname of the member switch |
| OCT hpnicfhgmpGrpMemberPassword | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.5 | OCTET STRING | read-write | Member password for joining a cluster |
| OCT hpnicfhgmpGrpMemberPlatform | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.6 | OCTET STRING | read-only | Set the hardware platform. A null string indicates the information does not exist in the device adjacency table. |
| INT hpnicfhgmpGrpMemberStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.7 | INTEGER | read-only | Member status on the administrator switch, use for displaying the network management status. |
| I32 hpnicfhgmpGrpMemberDisconCount | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.8 | Integer32 | read-only | Count of inside communication disconnection between the member switch and the administrator switch. |
| I32 hpnicfhgmpGrpMemberEnrollTime | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.9 | Integer32 | read-only | Enrollment time of the member, measured in seconds. |
| ROW hpnicfhgmpGrpMemberOperate | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.14.1.10 | RowStatus | read-write | Operation indication field, indicates the operation of adding/removing a member by the network management agent. |
| hpnicfhgmpMemberResetTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.15 | not-accessible | Reset a member switch in the cluster. | |
| hpnicfhgmpMemberResetEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.15.1 | not-accessible | ||
| OCT hpnicfhgmpMemberResetMAC | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.15.1.1 | OCTET STRING | read-only | The management MAC address of the switch to be reset, which is the unique identifier of the switch. |
| INT hpnicfhgmpMemberEraseflash | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.15.1.2 | INTEGER | read-write | Whether to erase the configuration file from the flash after resetting the switch. Read this node, cannotget(65535) will be returned. |
| INT hpnicfhgmpClusterRole | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.16 | INTEGER | read-only | This switch's role in cluster. |
| INT hpnicfhgmpClusterMaxPoolNum | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.17 | INTEGER | read-only | Max switch members that the cluster can support(include administrator switch). |
| OCT hpnicfhgmpClusterCmdSwMac | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.18 | OCTET STRING | read-only | The MAC address of administrator switch. It will be filled with zero when not be a member of cluster. |
| INT hpnicfhgmpRun | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.19 | INTEGER | read-write | Enable cluster on this switch. |
| hpnicfhgmpProtocolMac | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.22 | |||
| MAC hpnicfhgmpClusterProtocolMac | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.22.1 | MacAddress | read-write | Protocol MAC of HGMP protocol family. All multicast packets of this protocol family use this MAC as destination MAC. |
| hpnicfhgmpTopologyManagement | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23 | |||
| hpnicfhgmpWhitelistTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.1 | not-accessible | Cluster switches white list table. White list topology is the topology which has been affirmed by network administrator in a cluster, and all devices in white list topology are recorded in this table. Against to white list table, black list table records the devices which are denied to join in cluster. Adding a black list device to white list table will cause a failure. | |
| hpnicfhgmpWhitelistEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.1.1 | not-accessible | Entry items | |
| OCT hpnicfhgmpWhitelistDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.1.1.1 | OCTET STRING | not-accessible | Unique identifier indicating a white list switch. Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. For example, if the MAC is 000f-e459-000a, the value of this object is an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'. |
| I32 hpnicfhgmpWhitelistSerial | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.1.1.2 | Integer32 | read-only | When adding member switch to the cluster, the administrator switch will assign an unique integer to identify it. 0xffff means invalid value for this object. |
| ROW hpnicfhgmpWhitelistRowStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.1.1.3 | RowStatus | read-create | The row status of this table. |
| hpnicfhgmpWhitelistNbTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2 | not-accessible | Cluster switches white list neighboring information table. White list neighbor table records all neighbor devices for every white list device. In fact, white list neighbor table displays the whole white list topology. | |
| hpnicfhgmpWhitelistNbEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2.1 | not-accessible | Entry items | |
| I32 hpnicfhgmpWhitelistNbIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2.1.1 | Integer32 | not-accessible | Index of a switch which is the neighbor of a white list switch identified by 'hgmpWhitelistDeviceId'. |
| OCT hpnicfhgmpWhitelistNbDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2.1.2 | OCTET STRING | read-only | Unique identifier indicating a neighbor switch of a white list switch. Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. For example, if the MAC is 000f-e459-000a, the value of this object is an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'. |
| OCT hpnicfhgmpWhitelistPortName | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2.1.3 | OCTET STRING | read-only | The name of the port which a white list switch connects to the neighbor specified by 'hgmpWhitelistNbIndex'. |
| OCT hpnicfhgmpWhitelistNbPortName | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.2.1.4 | OCTET STRING | read-only | The name of the port which a neighbor device connects to the white list switch specified by 'hgmpWhitelistDeviceId'. |
| hpnicfhgmpBlacklistTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3 | not-accessible | Cluster switches black list table. The black list table records all black list devices, and a device in black list is not permitted to join in any cluster. | |
| hpnicfhgmpBlacklistEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3.1 | not-accessible | Entry items | |
| OCT hpnicfhgmpBlacklistDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3.1.1 | OCTET STRING | not-accessible | Unique identifier indicating a black list switch. Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. For example, if the MAC is 000f-e459-000a, the value of this object is an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'. |
| OCT hpnicfhgmpBlacklistAccessDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3.1.2 | OCTET STRING | read-only | Unique identifier indicating the access device of a black list switch. Tracing from a black list device to the cluster commander switch, the device which the black list switch directly connects to is the access device. Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. 10 bytes of 0xff means invalid value for this object. For example, if the MAC is 000f-e459-000a, the value of this object is an octet string: '00' '00' '00' '00' '00' '0f' 'e4' '59' '00' '0a'. |
| OCT hpnicfhgmpBlacklistAccessPortName | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3.1.3 | OCTET STRING | read-only | The port which the access device connecting to the black list switch is named access port, the object returns the access port name. An empty string means invalid value for this object. |
| ROW hpnicfhgmpBlacklistRowStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.23.3.1.4 | RowStatus | read-create | The row status of this table. |
| hpnicfhgmpMemberPriPortTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24 | not-accessible | This table contains port number for different network protocols on each member switch. The port number can be used to access a specified member switch with specified protocol and private IP address. | |
| hpnicfhgmpMemberPriPortEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24.1 | not-accessible | Information about a specified member private port entry. The indexes of the entry are hpnicfhgmpGrpMemberDevId and hpnicfhgmpMemberPriPortProto, which indicate entries in the table. | |
| OCT hpnicfhgmpMemberDevId | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24.1.1 | OCTET STRING | read-only | Unique identifier indicating the switch in cluster. Value format of the this object is 'XXXXYYYYYY', in which 'XXXX' is is reserved as 4 bytes of 0x0, 'YYYYYY' is a MAC address. |
| U32 hpnicfhgmpMemberPriPortProto | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24.1.2 | Unsigned32 | not-accessible | The index of this table. Each instance value of this object corresponds to a different protocol. |
| STR hpnicfhgmpMemberPriPortProtoDescr | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24.1.3 | DisplayString | read-only | It describes the hpnicfhgmpMemberPriPortProtocol object value. For example, it is 'SNMP' when hpnicfhgmpMemberPriPortProtocol value is 1. |
| U32 hpnicfhgmpMemberPriPortNum | 1.3.6.1.4.1.11.2.14.11.15.8.7.1.24.1.4 | Unsigned32 | read-only | The private port number of member switch, used by specified hpnicfhgmpMemberPriPortProto. By using the private IP address, specified protocol and port number, other devices outside cluster can access member switch. The private IP address can be acquired by reading hpnicfhgmpGrpMemberIpAddr. |
| hpnicfStackObject | 1.3.6.1.4.1.11.2.14.11.15.8.7.2 | This MIB contains objects to manage the stack operations, which is used on lanswitch products. | ||
| hpnicfhgmpStackEventsV2 | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.0 | Definition point for Stack notifications. | ||
| NTF hpnicfhgmpStackMemberfailure | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.0.1 | When a stack member failure, send a snmp trap to the network management. | ||
| NTF hpnicfhgmpStackMemberRecover | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.0.2 | When a stack member Recover, send a snmp trap to the network management. | ||
| NTF hpnicfhgmpStackMemberStatusChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.0.3 | When a stack member status change, send a snmp trap to the network management. | ||
| I32 hpnicfhgmpStackMemberTableChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.1 | Integer32 | read-only | Change identifier of the stack member table. |
| I32 hpnicfhgmpStackMemberDisconRate | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.2 | Integer32 | read-only | Disconnection rate of the stack member switches. |
| INT hpnicfhgmpMainLanswitchFlag | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.3 | INTEGER | read-write | The status of the local switch in the stack. |
| IP hpnicfhgmpStackIpPoolStartIP | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.4 | IpAddress | read-write | The first address of the management IP network segment assigned by the master switch, which cannot be modified in the case that there is IP address assignment. |
| INT hpnicfhgmpStackIpPoolLength | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.5 | INTEGER | read-write | The length of the management IP segment assigned by the master switch, which cannot be modified in the case that there is IP address assignment. |
| hpnicfhgmpStackMemberTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6 | not-accessible | Stack member table. | |
| hpnicfhgmpStackMemberEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1 | not-accessible | ||
| OCT hpnicfhgmpStackMemberDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.1 | OCTET STRING | read-only | 2 bytes address type of the switch + 2 bytes zero + MAC address, expressed as a hexadecimal number string. |
| I32 hpnicfhgmpStackMemberSerial | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.2 | Integer32 | read-only | When adding a member switch to the stack, the master switch will assign an unique integer to identify it. |
| IP hpnicfhgmpStackMemberIpAddr | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.3 | IpAddress | read-only | The private member IP address for the communication inside the stack. |
| OCT hpnicfhgmpStackMemberName | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.4 | OCTET STRING | read-only | Hostname of the member switch. |
| OCT hpnicfhgmpStackMemberPassword | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.5 | OCTET STRING | read-only | Member password for joining a stack. |
| OCT hpnicfhgmpStackMemberPlatform | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.6 | OCTET STRING | read-only | Set the hardware platform. A null string indicates the information does not exist in the device adjacency table. |
| INT hpnicfhgmpStackMemberStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.7 | INTEGER | read-only | Member status on the master switch, use for displaying the network management status. |
| I32 hpnicfhgmpStackMemberDisconCount | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.8 | Integer32 | read-only | Count of inside communication disconnection between the member switch and the master switch. |
| I32 hpnicfhgmpStackMemberEnrollTime | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.6.1.9 | Integer32 | read-only | Enrollment time of the member, measured in seconds. |
| INT hpnicfhgmpStackRole | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.7 | INTEGER | read-only | This switch's role status in stack. |
| INT hpnicfhgmpStackMaxPoolNum | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.8 | INTEGER | read-only | Max switch members in one stack that the switch support (include main switch). |
| OCT hpnicfhgmpStackMainSwMac | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.9 | OCTET STRING | read-only | The MAC address of main switch. It will be 00.00.00 when not be a member of stack. |
| IP hpnicfhgmpStackIpPoolMask | 1.3.6.1.4.1.11.2.14.11.15.8.7.2.10 | IpAddress | read-write | The mask of the management IP segment assigned by the master switch, which cannot be modified in the case that there is IP address assignment. |
| hpnicfNTDPObject | 1.3.6.1.4.1.11.2.14.11.15.8.7.4 | This MIB contains objects to manage the ntdp operations, which are used on lanswitch products. | ||
| I32 hpnicfhgmpNTDPCollectTopTime | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.1 | Integer32 | read-write | Topology collection interval of the administrator switch of the cluster, measured in minutes. |
| I32 hpnicfhgmpNTDPHopRange | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.2 | Integer32 | read-write | Range of the topology collection of the administrator switch |
| INT hpnicfhgmpNTDPRun | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.3 | INTEGER | read-write | Enable/Disable the NTDP function on the switch. |
| I32 hpnicfhgmpNTDPPortDelay | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.4 | Integer32 | read-write | Set the delay to forward the topology request via the ports, measured in milliseconds. |
| I32 hpnicfhgmpNTDPHopDelay | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.5 | Integer32 | read-write | Set the delay to forward the topology request from every hop, measured in milliseconds. |
| I32 hpnicfhgmpNTDPLastTopCollectDuration | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.6 | Integer32 | read-only | Duration of the latest overall topology collection, a performance count measured in seconds. |
| I32 hpnicfhgmpNTDPCacheChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.7 | Integer32 | read-only | Add 1 when the device table changes. The network administrator will check if it has changed before accessing the table. If it has not changed, he will not access again. |
| I32 hpnicfhgmpNTDPTOPTableChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.8 | Integer32 | read-only | Add 1 when the topology table changes. The network administrator will check if it has changed before accessing the table. If it has not changed, he will not access again. |
| hpnicfhgmpNTDPInterfaceTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.9 | not-accessible | Enable/Disable the NTDP on the switch port. | |
| hpnicfhgmpNTDPInterfaceEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.9.1 | not-accessible | ||
| I32 hpnicfhgmpNTDPInterfaceIfIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.9.1.1 | Integer32 | read-only | Unique identifier an interface of the device. |
| INT hpnicfhgmpNTDPInterfaceEnable | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.9.1.2 | INTEGER | read-write | If it is true, the device will send and receive the NTDP packets via the interface. To disable the NTDP function on the interface, set the entry as false. |
| hpnicfhgmpNTDPCacheTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10 | not-accessible | Access the information about the switch from the topology table. | |
| hpnicfhgmpNTDPCacheEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1 | not-accessible | ||
| I32 hpnicfhgmpNTDPCacheHashIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.1 | Integer32 | read-only | Our NTDP information is saved in the HASH table on the administrator switch. Using DeviceID as index will lead to the comparison of a large amount of character strings, which puts too many burdens on the administrator switch. A HAHSIndex is added to reduce the character string comparison to the least range. |
| OCT hpnicfhgmpNTDPCacheDeviceID | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.2 | OCTET STRING | read-only | 2 bytes address type of the member switch + 2 bytes zero + MAC address, expressed as a character string of the hexadecimal number. |
| OCT hpnicfhgmpNTDPCacheClusterName | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.3 | OCTET STRING | read-only | Name of the cluster including the device. |
| INT hpnicfhgmpNTDPCacheClusterRole | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.4 | INTEGER | read-only | Cluster role of the current device, which can be a administrator switch (0x01), member switch(0x02), backup switch(0x03), candidate switch(0x10) or an independent switch (incapable of cluster member) (0x11). |
| INT hpnicfhgmpNTDPCacheCapabilities | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.5 | INTEGER | read-only | The capabilities of the device. FF indicates that the field was not included in in the latest NTDP packet. |
| OCT hpnicfhgmpNTDPCacheVersion | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.6 | OCTET STRING | read-only | The version information of the corresponding device. A null string indicates that the field was not included in in the latest NTDP packet. |
| OCT hpnicfhgmpNTDPCachePlatform | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.7 | OCTET STRING | read-only | Hardware platform. A null string indicates that the field was not included in the latest NTDP packet. |
| INT hpnicfhgmpNTDPCacheMngVLAN | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.8 | INTEGER | read-only | The management VLAN ID of the device. |
| INT hpnicfhgmpNTDPCacheHop | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.10.1.9 | INTEGER | read-only | Hops to this switch. |
| hpnicfhgmpNTDPTopTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11 | not-accessible | Access the topology structure collected by the NTDP. | |
| hpnicfhgmpNTDPTopEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1 | not-accessible | ||
| I32 hpnicfhgmpNTDPTopHashIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.1 | Integer32 | read-only | Our NTDP information is saved in the HASH table on the administrator switch. Using DeviceID as index will lead to the comparison of a large amount of character strings, which puts too many burdens on the administrator switch. A HAHSIndex is added to reduce the character string comparison to the least range. |
| OCT hpnicfhgmpNTDPTopEdgeStartDevID | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.2 | OCTET STRING | read-only | 2 bytes address type of the member switch + 2 bytes zero + MAC address, expressed as a character string of the hexadecimal number. |
| I32 hpnicfhgmpNTDPTopEdgeIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.3 | Integer32 | read-only | Edge index of this entry in the data structure. |
| OCT hpnicfhgmpNTDPTopEdgeEndDevID | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.4 | OCTET STRING | read-only | 2 bytes address type of the member switch + 2 bytes zero + MAC address, expressed as a character string of the hexadecimal number. |
| OCT hpnicfhgmpNTDPTopEdgeStartPort | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.5 | OCTET STRING | read-only | The number of the first port of a topology edge. Interface type + card number / slot number / sequence number. |
| INT hpnicfhgmpNTDPTopEdgeStartPortFullDuplex | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.6 | INTEGER | read-only | The full-duplex status of the first port on a topology edge. |
| I32 hpnicfhgmpNTDPTopEdgeStartPortSpeed | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.7 | Integer32 | read-only | The speed of the first port on a topology edge. |
| OCT hpnicfhgmpNTDPTopEdgeEndPort | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.8 | OCTET STRING | read-only | The number of the last port of a topology edge. Interface type + card number / slot number / sequence number. |
| INT hpnicfhgmpNTDPTopLinkStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.4.11.1.11 | INTEGER | read-only | In STP or RSTP, it describes link status according to port STP steady status. In MSTP it describes STP steady status of the instance which management VLAN belongs to. Either 'hgmpNTDPTopEdgeStartPort' or 'hgmpNTDPTopEdgeEndPort' STP steady status is 'blocking', this object is 'blocking', otherwise is 'forwarding'. If STP or MSTP is disabled, this object is 'forwarding'. |
| hpnicfNDPObject | 1.3.6.1.4.1.11.2.14.11.15.8.7.5 | This MIB contains objects to manage the ndp operations, which are used on lanswitch products. | ||
| INT hpnicfNDPStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.1 | INTEGER | read-write | NDP protocol module enable flag |
| I32 hpnicfNDPHelloTimer | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.2 | Integer32 | read-write | NDP packet transmission interval, measured in seconds. |
| I32 hpnicfNDPAgingTime | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.3 | Integer32 | read-write | How long the NDP information of the local switch can be hold in the adjacent switch, measured in seconds. |
| C32 hpnicfNDPChange | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.4 | Counter32 | read-only | Change identifier of the Neighbor table |
| hpnicfNDPPortTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.5 | not-accessible | Configure to enable/disable the interface NDP of the switch. | |
| hpnicfNDPPortEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.5.1 | not-accessible | ||
| I32 hpnicfNDPIfIndex | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.5.1.1 | Integer32 | read-only | Unique identifier of an interface of the device. |
| INT hpnicfNDPPortStatus | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.5.1.2 | INTEGER | read-write | If it is enable, the device will send and receive the NDP packets via the interface. To disable the NDP function on the interface, set the entry as false. |
| hpnicfNDPPortNbTable | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6 | not-accessible | NDP neighbor information on the switch. | |
| hpnicfNDPPortNbEntry | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1 | not-accessible | ||
| OCT hpnicfNDPPortNbDeviceId | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.1 | OCTET STRING | read-only | 2 bytes address type of the member switch + 2 bytes zero + MAC address, expressed as a character string of the hexadecimal number. |
| OCT hpnicfNDPPortNbPortName | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.2 | OCTET STRING | read-only | Unique identifier of a port. A null string indicates that the field was not included in in the latest NDP packet. Interface type + card number / slot number / sequence number. |
| OCT hpnicfNDPPortNbDeviceName | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.3 | OCTET STRING | read-only | Device name. A null string indicates that the field was not included in the latest NDP packet. |
| INT hpnicfNDPPortNbPortMode | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.4 | INTEGER | read-only | The neighbor port duplex mode. |
| OCT hpnicfNDPPortNbProductVer | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.5 | OCTET STRING | read-only | Product version. A null string indicates that the field was not included in the latest NDP packet. |
| OCT hpnicfNDPPortNbHardVer | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.6 | OCTET STRING | read-only | Hardware version. A null string indicates that the field was not included in the latest NDP packet. |
| OCT hpnicfNDPPortNbBootromVer | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.7 | OCTET STRING | read-only | Bootrom version. A null string indicates that the field was not included in the latest NDP packet. |
| OCT hpnicfNDPPortNbSoftVer | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.8 | OCTET STRING | read-only | Software version. A null string indicates that the field was not included in the latest NDP packet. |
| I32 hpnicfNDPPortNbAgingtime | 1.3.6.1.4.1.11.2.14.11.15.8.7.5.6.1.9 | Integer32 | read-only | How long the NDP information of the local switch can be hold in the adjacent switch, measured in seconds. |
RFC description
Manages HP/H3C cluster and group management protocol (HGMP) operations for LAN switch topology and network clustering.
Start monitoring HP/H3C Comware LAN switch (clustered, HGMP) with a free 30-day trial of IPNetwork Monitor. Import MIBs, browse SNMP OIDs, create custom SNMP monitors, configure alerts, and monitor any SNMP-enabled network device from a single console.