hpnicfOltPortAlarmOamDisconnectionEnabled

Module: HPN-ICF-EPON-MIB

OID (symbolic): HPN-ICF-EPON-MIB::hpnicfOltPortAlarmOamDisconnectionEnabled

OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1.12

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: Behavior of Operations Administration and Maintenance(OAM) disconnection alarm. true(1) - alarm enable. false(2) - alarm disable.

What is hpnicfOltPortAlarmOamDisconnectionEnabled?

Enables (true, default) or disables the alarm for Operations, Administration and Maintenance (OAM) disconnection on this OLT port, i.e. when OAM contact with an ONU is lost.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1.12
snmpwalk -v2c -c public <target> HPN-ICF-EPON-MIB::hpnicfOltPortAlarmOamDisconnectionEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1.12.1
snmpget -v2c -c public <target> HPN-ICF-EPON-MIB::hpnicfOltPortAlarmOamDisconnectionEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1.12.1 s <value>

Start monitoring HP/H3C Comware-based EPON OLT and ONU access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EPON-MIB::hpnicfOltPortAlarmOamDisconnectionEnabled OID value, configure state conditions and alerts, and monitor any HP/H3C Comware-based EPON OLT and ONU access equipment from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.14icfCONFIG-MIB
1.3.6.1.4.1.11.2.14.11hpicfObjectsCONFIG-MIB
1.3.6.1.4.1.11.2.14.11.15hpnicfHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2hpnicfCommonHPN-ICF-OID-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42hpnicfEponHPN-ICF-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.14.11.15.2.42.1hpnicfEponMibObjectsHPN-ICF-EPON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.1.3hpnicfEponOltManHPN-ICF-EPON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4hpnicfOltPortAlarmThresholdTableHPN-ICF-EPON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1hpnicfOltPortAlarmThresholdEntryHPN-ICF-EPON-MIB
1.3.6.1.4.1.11.2.14.11.15.2.42.1.3.4.1.12hpnicfOltPortAlarmOamDisconnectionEnabledHPN-ICF-EPON-MIB