All MIBs › HPN-ICF-EPON-DEVICE-MIB › hpnicfEponDeviceObjectFecEnabled
hpnicfEponDeviceObjectFecEnabled
Module: HPN-ICF-EPON-DEVICE-MIB
OID (symbolic): HPN-ICF-EPON-DEVICE-MIB::hpnicfEponDeviceObjectFecEnabled
OID (numeric): 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This variable defines and provides information whether the EPON device uses FEC as defined in the [802.3ah] clause 65.2 for EPON. When noFECEnabled(1) the device does not support FEC mode When fecTxEnabled(2) the device supports the FEC transmission mode. When fecRxEnabled(3) the device supports the FEC Receive mode. When fecTxRxEnabled(4) the device supports the FEC transmission and receive mode. Writing can be done all the time. This attribute is relevant for an OLT and an ONU.
What is hpnicfEponDeviceObjectFecEnabled?
Controls Forward Error Correction (FEC) mode on the EPON link: noFecEnabled(1) disables it, fecTxEnabled(2)/fecRxEnabled(3) enable it in one direction, and fecTxRxEnabled(4) enables it both ways, per IEEE 802.3ah clause 65.2. An operator enables FEC to improve reliability over longer or noisier PON spans at some cost to overhead.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1.4 snmpwalk -v2c -c public <target> HPN-ICF-EPON-DEVICE-MIB::hpnicfEponDeviceObjectFecEnabled
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1.4.1 snmpget -v2c -c public <target> HPN-ICF-EPON-DEVICE-MIB::hpnicfEponDeviceObjectFecEnabled.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1.4.1 i <value>
Start monitoring HP/H3C Comware EPON OLT and ONU access equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HPN-ICF-EPON-DEVICE-MIB::hpnicfEponDeviceObjectFecEnabled OID value, configure state conditions and alerts, and monitor any HP/H3C Comware EPON OLT and ONU access equipment from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.15 | hpnicf | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2 | hpnicfCommon | HPN-ICF-OID-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42 | hpnicfEpon | HPN-ICF-OID-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4 | hpnicfEponDeviceMIB | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1 | hpnicfEponDeviceObjectMIB | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1 | hpnicfEponDeviceObjects | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1 | hpnicfEponDeviceControlObjects | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1 | hpnicfEponDeviceControlTable | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1 | hpnicfEponDeviceControlEntry | HPN-ICF-EPON-DEVICE-MIB |
| 1.3.6.1.4.1.11.2.14.11.15.2.42.4.1.1.1.1.1.4 | hpnicfEponDeviceObjectFecEnabled | HPN-ICF-EPON-DEVICE-MIB |