HP-VLAN-CAR-MIB :: snVLanCARDirection

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HP-VLAN-CAR-MIB › snVLanCARDirection

snVLanCARDirection

Module: HP-VLAN-CAR-MIB

OID (symbolic): HP-VLAN-CAR-MIB::snVLanCARDirection

OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1.1.2

Node type: OBJECT-TYPE

Type: PacketSource

Access: read-only

Description: The input or output transmission direction for the Rate Limit object.

What is snVLanCARDirection?

This object indicates whether a given rate-limit entry applies to ingress (input) or egress (output) traffic on the VLAN, and forms part of the table's index alongside the VLAN ID and row index. Admins use it to distinguish rate limits that throttle traffic entering a VLAN from those throttling traffic leaving it, since the two are configured and reported separately. For instance, an admin capping upload traffic on VLAN 50 would look for the entry where this object indicates the input direction.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1.1.2
snmpwalk -v2c -c public <target> HP-VLAN-CAR-MIB::snVLanCARDirection

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1.1.2.1
snmpget -v2c -c public <target> HP-VLAN-CAR-MIB::snVLanCARDirection.1

Start monitoring HP (Foundry/Brocade-lineage) switch/router (per-VLAN Committed Access Rate policing) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-VLAN-CAR-MIB::snVLanCARDirection OID value, configure state conditions and alerts, and monitor any HP (Foundry/Brocade-lineage) switch/router (per-VLAN Committed Access Rate policing) from a single console.

OID Breakdown

Upper-level ancestors (15 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.11hpCLJ8500-MIB
1.3.6.1.4.1.11.2nmCLJ8500-MIB
1.3.6.1.4.1.11.2.3hpsystemCLJ8500-MIB
1.3.6.1.4.1.11.2.3.7netElementHP-BASE-MIB
1.3.6.1.4.1.11.2.3.7.11hpEtherSwitchHP-BASE-MIB
1.3.6.1.4.1.11.2.3.7.11.12hpSwitchCoreHP-SN-ROOT-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1switchHP-SN-ROOT-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1.3snSwitchHP-SN-ROOT-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1.3.17snVLanCARHP-SN-SWITCH-GROUP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1snVLanCARsHP-VLAN-CAR-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1snVLanCARTableHP-VLAN-CAR-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1.1snVLanCAREntryHP-VLAN-CAR-MIB
1.3.6.1.4.1.11.2.3.7.11.12.1.3.17.1.1.1.2snVLanCARDirectionHP-VLAN-CAR-MIB