All MIBs › HP-MEMPROC-MIB › hpmpCPUPctBusy
hpmpCPUPctBusy
Module: HP-MEMPROC-MIB
OID (symbolic): HP-MEMPROC-MIB::hpmpCPUPctBusy
OID (numeric): 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1.1.1.5
Node type: OBJECT-TYPE
Type: Gauge32
Access: read-only
Description: This object reports the percentage time the CPU was actively engaged during the last interval.
What is hpmpCPUPctBusy?
This read-only gauge reports the percentage of time the CPU was actively engaged during the last measurement interval. Admins use it as a direct, easy-to-interpret CPU utilization figure for alerting or dashboards, complementing the run-queue-based load averages. For example, a value of 92 percent would indicate the CPU was almost continuously busy during the last interval, warranting a closer look at what process is consuming it.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1.1.1.5 snmpwalk -v2c -c public <target> HP-MEMPROC-MIB::hpmpCPUPctBusy
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1.1.1.5.1 snmpget -v2c -c public <target> HP-MEMPROC-MIB::hpmpCPUPctBusy.1
Start monitoring HP ProCurve switch/router (CPU/memory utilization) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-MEMPROC-MIB::hpmpCPUPctBusy OID value, configure state conditions and alerts, and monitor any HP ProCurve switch/router (CPU/memory utilization) from a single console.
How to Use in IPNetwork Monitor
OID Breakdown
Upper-level ancestors (14 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3 | hpsystem | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.3.7 | netElement | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11 | hpEtherSwitch | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17 | hpSwitchJ4819A | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7 | hpSwitchModuleJ8162A | HP-BASE-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1 | hpProcurveCommon | HP-BASE-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5 | hpMemprocMIB | HP-MEMPROC-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1 | hpMemprocMIBObjects | HP-MEMPROC-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1 | hpmpCPU | HP-MEMPROC-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1.1 | hpmpCPUTable | HP-MEMPROC-MIB |
| 1.3.6.1.4.1.11.2.3.7.11.17.7.1.5.1.1.1.1 | hpmpCPUEntry | HP-MEMPROC-MIB |