Module: HP-ICF-URPF-MIB
OID (symbolic): HP-ICF-URPF-MIB::hpicfUrpfConfigLogging
OID (numeric): 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1.6
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: Is logging of dropped packets enabled. true(1) - logging enabled; false(2) - logging disabled.
What is hpicfUrpfConfigLogging?
This read-write flag, defaulting to false, controls whether packets dropped by URPF on this interface are logged. Admins enable it to get visibility into what traffic URPF is actually blocking, useful for confirming the feature is working as intended or investigating suspected spoofing attempts. An admin who just enabled strict URPF on a new interface would set this to true(1) temporarily to verify no legitimate traffic is being unexpectedly dropped.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1.6 snmpwalk -v2c -c public <target> HP-ICF-URPF-MIB::hpicfUrpfConfigLogging
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1.6.1 snmpget -v2c -c public <target> HP-ICF-URPF-MIB::hpicfUrpfConfigLogging.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1.6.1 s <value>
Start monitoring HP ProCurve switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HP-ICF-URPF-MIB::hpicfUrpfConfigLogging OID value, configure state conditions and alerts, and monitor any HP ProCurve switches from a single console.
OID Breakdown
Upper-level ancestors (13 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.11 | hp | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2 | nm | CLJ8500-MIB |
| 1.3.6.1.4.1.11.2.14 | icf | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11 | hpicfObjects | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5 | hpicfSwitch | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1 | hpSwitch | CONFIG-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.131 | hpicfUrpfMIB | HP-ICF-OID |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.11.2.14.11.5.1.131.1 | hpicfUrpfConfig | HP-ICF-URPF-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3 | hpicfUrpfConfigTable | HP-ICF-URPF-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1 | hpicfUrpfConfigEntry | HP-ICF-URPF-MIB |
| 1.3.6.1.4.1.11.2.14.11.5.1.131.1.3.1.6 | hpicfUrpfConfigLogging | HP-ICF-URPF-MIB |