HMIOMODULE-SNMP-MIB :: hmIOModValueDigOutputValue

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HMIOMODULE-SNMP-MIB › hmIOModValueDigOutputValue

hmIOModValueDigOutputValue

Module: HMIOMODULE-SNMP-MIB

OID (symbolic): HMIOMODULE-SNMP-MIB::hmIOModValueDigOutputValue

OID (numeric): 1.3.6.1.4.1.248.14.1.13.2.2.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Status of the output. If the value is not-available(0), then the IO module is not plugged in, if the value is high(1), the output has high (+24V) value, if the value is low(2), the output has low (0V) value. If the value is invalid (3), the output has low (0V) value and the IO input source is configured but can not be read. If the value is not-configured (4), the output has low (0V) value and has no IO input source configured.

What is hmIOModValueDigOutputValue?

This object reports the current status of a digital output: not-available(0) if the IO module isn't plugged in, high(1) or low(2) reflecting its actual voltage state, invalid(3) if a configured input source can't be read (leaving the output at low), or not-configured(4) if no source has been set up. Admins poll this to confirm an output is correctly reflecting its mirrored input source rather than sitting in a fallback or error state. For example, hmIOModValueDigOutputValue reporting invalid(3) would alert an admin that this output's configured remote input source is currently unreachable, even though the physical output itself remains at low.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.14.1.13.2.2.1.3
snmpwalk -v2c -c public <target> HMIOMODULE-SNMP-MIB::hmIOModValueDigOutputValue

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.14.1.13.2.2.1.3.1
snmpget -v2c -c public <target> HMIOMODULE-SNMP-MIB::hmIOModValueDigOutputValue.1

Start monitoring Hirschmann industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HMIOMODULE-SNMP-MIB::hmIOModValueDigOutputValue OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switch with digital I/O expansion module from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.14hmConfigurationHMPRIV-MGMT-SNMP-MIB
1.3.6.1.4.1.248.14.1hmChassisHMPRIV-MGMT-SNMP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.14.1.13hmIOModuleGroupHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.2hmIOModuleValueGroupHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.2.2hmIOModValueDigOutputTableHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.2.2.1hmIOModValueDigOutputEntryHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.2.2.1.3hmIOModValueDigOutputValueHMIOMODULE-SNMP-MIB