HMIOMODULE-SNMP-MIB :: hmIOModConfigDigOutputLogEvent

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HMIOMODULE-SNMP-MIB › hmIOModConfigDigOutputLogEvent

hmIOModConfigDigOutputLogEvent

Module: HMIOMODULE-SNMP-MIB

OID (symbolic): HMIOMODULE-SNMP-MIB::hmIOModConfigDigOutputLogEvent

OID (numeric): 1.3.6.1.4.1.248.14.1.13.1.3.1.3

Node type: OBJECT-TYPE

Type: HmEnabledStatus

Access: read-write

Description: Trigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the output state changes. The output state will be checked acording to the refresh interval entered in hmIOModConfigDigOutputRefreshInterval.

What is hmIOModConfigDigOutputLogEvent?

This object controls whether the device writes an event log entry whenever this specific digital output's state changes, checked according to the configured output refresh interval. Admins enable(1) this to keep a record of output transitions, such as when a relay output engages or disengages. For example, enabling hmIOModConfigDigOutputLogEvent on an output driving an alarm relay logs every time that relay's state flips.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.14.1.13.1.3.1.3
snmpwalk -v2c -c public <target> HMIOMODULE-SNMP-MIB::hmIOModConfigDigOutputLogEvent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.14.1.13.1.3.1.3.1
snmpget -v2c -c public <target> HMIOMODULE-SNMP-MIB::hmIOModConfigDigOutputLogEvent.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.14.1.13.1.3.1.3.1 s <value>

Start monitoring Hirschmann industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HMIOMODULE-SNMP-MIB::hmIOModConfigDigOutputLogEvent OID value, configure state conditions and alerts, and monitor any Hirschmann industrial Ethernet switch with digital I/O expansion module from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.14hmConfigurationHMPRIV-MGMT-SNMP-MIB
1.3.6.1.4.1.248.14.1hmChassisHMPRIV-MGMT-SNMP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.14.1.13hmIOModuleGroupHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.1hmIOModuleConfigGroupHMIOMODULE-SNMP-MIB
1.3.6.1.4.1.248.14.1.13.1.3hmIOModConfigDigOutputTableHMIOMODULE-SNMP-MIB