HM2-TIMESYNC-MIB :: hm2Ptp2TCFaulty

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-TIMESYNC-MIB › hm2Ptp2TCFaulty

hm2Ptp2TCFaulty

Module: HM2-TIMESYNC-MIB

OID (symbolic): HM2-TIMESYNC-MIB::hm2Ptp2TCFaulty

OID (numeric): 1.3.6.1.4.1.248.11.50.1.4.3.2.1.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-only

Description: True if port is in Faulty state.

What is hm2Ptp2TCFaulty?

Indicates whether this transparent-clock port is currently in the PTP Faulty state, which typically means it has stopped participating normally in the protocol and needs attention.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.4.3.2.1.3
snmpwalk -v2c -c public <target> HM2-TIMESYNC-MIB::hm2Ptp2TCFaulty

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.4.3.2.1.3.1
snmpget -v2c -c public <target> HM2-TIMESYNC-MIB::hm2Ptp2TCFaulty.1

Start monitoring Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-TIMESYNC-MIB::hm2Ptp2TCFaulty OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.50hm2TimeSyncMibHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1hm2TimeSyncMibObjectsHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4hm2PtpGroupHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.3hm2Ptp2TCObjectsHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.3.2hm2Ptp2TCPortTableHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.3.2.1hm2Ptp2TCPortEntryHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.3.2.1.3hm2Ptp2TCFaultyHM2-TIMESYNC-MIB