HM2-TIMESYNC-MIB :: hm2Ptp2GrandmasterPriority1

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-TIMESYNC-MIB › hm2Ptp2GrandmasterPriority1

hm2Ptp2GrandmasterPriority1

Module: HM2-TIMESYNC-MIB

OID (symbolic): HM2-TIMESYNC-MIB::hm2Ptp2GrandmasterPriority1

OID (numeric): 1.3.6.1.4.1.248.11.50.1.4.2.1.22

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: Priority 1 value of the grand master clock.

What is hm2Ptp2GrandmasterPriority1?

Reports the priority1 value the current grandmaster clock is advertising, the primary tiebreaker PTP used when it was elected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.4.2.1.22
snmpwalk -v2c -c public <target> HM2-TIMESYNC-MIB::hm2Ptp2GrandmasterPriority1

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.4.2.1.22.1
snmpget -v2c -c public <target> HM2-TIMESYNC-MIB::hm2Ptp2GrandmasterPriority1.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> hm2Ptp2GrandmasterPriority1.1

Start monitoring Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-TIMESYNC-MIB::hm2Ptp2GrandmasterPriority1 OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.50hm2TimeSyncMibHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1hm2TimeSyncMibObjectsHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4hm2PtpGroupHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.2hm2Ptp2ObjectsHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.2.1hm2Ptp2ConfigurationHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.4.2.1.22hm2Ptp2GrandmasterPriority1HM2-TIMESYNC-MIB