HM2-TIMESYNC-MIB :: hm2IrigMode

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-TIMESYNC-MIB › hm2IrigMode

hm2IrigMode

Module: HM2-TIMESYNC-MIB

OID (symbolic): HM2-TIMESYNC-MIB::hm2IrigMode

OID (numeric): 1.3.6.1.4.1.248.11.50.1.5.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Set the IRIG Mode, allowed values: (See https://wsmrc2vger.wsmr.army.mil/rcc/manuals/200-04/TT-45.pdf) irig-b000 (0) - Mode IRIG B000, BCDtoy, CF, SBS irig-b001 (1) - Mode IRIG B001, BCDtoy, CF irig-b002 (2) - Mode IRIG B002, BCDtoy irig-b003 (3) - Mode IRIG B003, BCDtoy, SBS irig-b004 (4) - Mode IRIG B004, BCDtoy, BCDyear, CF, SBS irig-b005 (5) - Mode IRIG B005, BCDtoy, BCDyear, CF irig-b006 (6) - Mode IRIG B006, BCDtoy, BCDyear irig-b007 (7) - Mode IRIG B007, BCDtoy, BCDyear, SBS with BCDtoy: binary coded decimal time of year BCDyear: binary coded decimal year CF: control functions SBS: straight binary seconds of day only modes b002,B003,B006 and b007 are supported.

What is hm2IrigMode?

Selects which IRIG-B format variant (per IRIG standard 200-04) is generated on the output, such as b002/b003/b006/b007 -- the description notes only these four of the eight listed enum values are actually supported by this device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.5.2
snmpwalk -v2c -c public <target> HM2-TIMESYNC-MIB::hm2IrigMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.50.1.5.2.1
snmpget -v2c -c public <target> HM2-TIMESYNC-MIB::hm2IrigMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.50.1.5.2.1 i <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-TIMESYNC-MIB::hm2IrigMode OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (NTP/SNTP/PTP time sync) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.50hm2TimeSyncMibHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1hm2TimeSyncMibObjectsHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.5hm2IrigGroupHM2-TIMESYNC-MIB
1.3.6.1.4.1.248.11.50.1.5.2hm2IrigModeHM2-TIMESYNC-MIB