All MIBs › HM2-L2REDUNDANCY-MIB › hm2RingCplConfigOperState
hm2RingCplConfigOperState
Module: HM2-L2REDUNDANCY-MIB
OID (symbolic): HM2-L2REDUNDANCY-MIB::hm2RingCplConfigOperState
OID (numeric): 1.3.6.1.4.1.248.11.40.1.8.1.1.13
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Operational state of the ring coupling configuration.
slaveCouplingLinkError(2) indicates that the coupling link is not connected with the coupling port of the slave but with another port of the slave.
In case of outband control additional failures can be detected: slaveControlLinkError(3) indicates that the control port of the slave has either no link or the link fails. masterControlLinkError(4) indicates that the control link is not connected with the control port of the master but with another port of the master. twoSlaves(5) is returned when two slaves are connected by the control line.
localPartnerLinkError(6) indicates that the partner coupling link is not connected with the partner port of the slave but with another port of the slave in local control mode. localInvalidCouplingPort(7) indicates that in local mode the coupling line is connected to another switch and not on the same switch like the partner line.
couplingPortNotAvailable(8), controlPortNotAvailable(9) and partnerPortNotAvailable(10) indicate that this port is not available because the module related to this port is not available or the port does not exist on this module.
What is hm2RingCplConfigOperState?
Reports which specific ring-coupling misconfiguration is present (wrong port wiring on slave or master, two slaves detected, missing local partner link, module not available, etc.) or noError, serving as the main troubleshooting field for a broken ring coupling.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.40.1.8.1.1.13 snmpwalk -v2c -c public <target> HM2-L2REDUNDANCY-MIB::hm2RingCplConfigOperState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.40.1.8.1.1.13.1 snmpget -v2c -c public <target> HM2-L2REDUNDANCY-MIB::hm2RingCplConfigOperState.1
Start monitoring Hirschmann HiOS industrial Ethernet switch (MRP ring/RSTP redundancy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-L2REDUNDANCY-MIB::hm2RingCplConfigOperState OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (MRP ring/RSTP redundancy) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.248 | hirschmann | HM2-TC-MIB |
| 1.3.6.1.4.1.248.11 | hm2ConfigurationMibs | HM2-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.248.11.40 | hm2L2RedundancyMib | HM2-L2REDUNDANCY-MIB |
| 1.3.6.1.4.1.248.11.40.1 | hm2L2RedundancyMibObjects | HM2-L2REDUNDANCY-MIB |
| 1.3.6.1.4.1.248.11.40.1.8 | hm2RingCouplingMibGroup | HM2-L2REDUNDANCY-MIB |
| 1.3.6.1.4.1.248.11.40.1.8.1 | hm2RingCouplingTable | HM2-L2REDUNDANCY-MIB |
| 1.3.6.1.4.1.248.11.40.1.8.1.1 | hm2RingCouplingEntry | HM2-L2REDUNDANCY-MIB |
| 1.3.6.1.4.1.248.11.40.1.8.1.1.13 | hm2RingCplConfigOperState | HM2-L2REDUNDANCY-MIB |