HM2-IOMODULE-MIB :: hm2IOModConfigDigOutputSourceModID

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-IOMODULE-MIB › hm2IOModConfigDigOutputSourceModID

hm2IOModConfigDigOutputSourceModID

Module: HM2-IOMODULE-MIB

OID (symbolic): HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceModID

OID (numeric): 1.3.6.1.4.1.248.11.100.1.1.3.1.8

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The module ID of an input mirrored to the output. Module ID 0 corresponds to the power supply module. Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0.

What is hm2IOModConfigDigOutputSourceModID?

This read-write Integer32 (0..7) identifies which IO module on the source device provides the input this output mirrors, with module ID 0 reserved for the power supply module. It's ignored when hm2IOModConfigDigOutputSourceAddress is 0.0.0.0, i.e. when mirroring is disabled. For example, an admin would set this to 2 to mirror an input from the third IO module slot on the source device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.8
snmpwalk -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceModID

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.8.1
snmpget -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceModID.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.8.1 i <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceModID OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.100hm2IOModuleMibHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1hm2IOModuleMibObjectsHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1hm2IOModConfigGroupHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3hm2IOModConfigDigOutputTableHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1hm2IOModConfigDigOutputEntryHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1.8hm2IOModConfigDigOutputSourceModIDHM2-IOMODULE-MIB