All MIBs › HM2-IOMODULE-MIB › hm2IOModConfigDigOutputSourceID
hm2IOModConfigDigOutputSourceID
Module: HM2-IOMODULE-MIB
OID (symbolic): HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceID
OID (numeric): 1.3.6.1.4.1.248.11.100.1.1.3.1.9
Node type: OBJECT-TYPE
Type: Integer32
Access: read-write
Description: The ID of an input mirrored to the output. Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0.
What is hm2IOModConfigDigOutputSourceID?
This read-write Integer32 (1..4) identifies which specific input (1 through 4) on the source module this output mirrors. Like hm2IOModConfigDigOutputSourceModID, it's ignored when the source address is 0.0.0.0. For example, setting this to 3 together with a source module ID configures the output to follow input 3 on that remote module.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.9 snmpwalk -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceID
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.9.1 snmpget -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceID.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.9.1 i <value>
Start monitoring Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceID OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.248 | hirschmann | HIRSCHMANN-GENERIC-ERROR-MIB |
| 1.3.6.1.4.1.248.11 | hm2ConfigurationMibs | HM2-TC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.248.11.100 | hm2IOModuleMib | HM2-IOMODULE-MIB |
| 1.3.6.1.4.1.248.11.100.1 | hm2IOModuleMibObjects | HM2-IOMODULE-MIB |
| 1.3.6.1.4.1.248.11.100.1.1 | hm2IOModConfigGroup | HM2-IOMODULE-MIB |
| 1.3.6.1.4.1.248.11.100.1.1.3 | hm2IOModConfigDigOutputTable | HM2-IOMODULE-MIB |
| 1.3.6.1.4.1.248.11.100.1.1.3.1 | hm2IOModConfigDigOutputEntry | HM2-IOMODULE-MIB |
| 1.3.6.1.4.1.248.11.100.1.1.3.1.9 | hm2IOModConfigDigOutputSourceID | HM2-IOMODULE-MIB |