HM2-IOMODULE-MIB :: hm2IOModConfigDigOutputSourceAddressType

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-IOMODULE-MIB › hm2IOModConfigDigOutputSourceAddressType

hm2IOModConfigDigOutputSourceAddressType

Module: HM2-IOMODULE-MIB

OID (symbolic): HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceAddressType

OID (numeric): 1.3.6.1.4.1.248.11.100.1.1.3.1.5

Node type: OBJECT-TYPE

Type: InetAddressType

Access: read-write

Description: Address type of an input mirrored to the output. Currently, only ipv4 is supported.

What is hm2IOModConfigDigOutputSourceAddressType?

This read-write InetAddressType selects the address family used for the source input's IP address that this output mirrors, and the MIB currently supports only ipv4. Admins set it alongside hm2IOModConfigDigOutputSourceAddress to identify where the mirrored input value comes from. For example, this stays at its default ipv4(1) since IPv6 sources aren't yet supported by this table.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.5
snmpwalk -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceAddressType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.5.1
snmpget -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceAddressType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.5.1 s <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-IOMODULE-MIB::hm2IOModConfigDigOutputSourceAddressType OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.100hm2IOModuleMibHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1hm2IOModuleMibObjectsHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1hm2IOModConfigGroupHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3hm2IOModConfigDigOutputTableHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1hm2IOModConfigDigOutputEntryHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1.5hm2IOModConfigDigOutputSourceAddressTypeHM2-IOMODULE-MIB