HM2-IOMODULE-MIB :: hm2IOModConfigDigOutputLogEvent

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HM2-IOMODULE-MIB › hm2IOModConfigDigOutputLogEvent

hm2IOModConfigDigOutputLogEvent

Module: HM2-IOMODULE-MIB

OID (symbolic): HM2-IOMODULE-MIB::hm2IOModConfigDigOutputLogEvent

OID (numeric): 1.3.6.1.4.1.248.11.100.1.1.3.1.3

Node type: OBJECT-TYPE

Type: HmEnabledStatus

Access: read-write

Description: Trigger an event log when output status changes. If the value is disable (2), no event log entry will be written. If the value is enable (1), an event log entry will be written when the output state changes. The output state will be checked according to the refresh interval entered in hm2IOModConfigDigOutputRefreshInterval.

What is hm2IOModConfigDigOutputLogEvent?

This read-write HmEnabledStatus setting controls whether the device writes an event log entry whenever a digital output's state changes, per the interval in hm2IOModConfigDigOutputRefreshInterval. When enabled(1), each output transition is recorded for later audit. For example, an admin would enable this on a relay output driving external equipment to log every time it switched on or off.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.3
snmpwalk -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputLogEvent

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.3.1
snmpget -v2c -c public <target> HM2-IOMODULE-MIB::hm2IOModConfigDigOutputLogEvent.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.100.1.1.3.1.3.1 s <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-IOMODULE-MIB::hm2IOModConfigDigOutputLogEvent OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch with digital I/O expansion module from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHIRSCHMANN-GENERIC-ERROR-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.100hm2IOModuleMibHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1hm2IOModuleMibObjectsHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1hm2IOModConfigGroupHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3hm2IOModConfigDigOutputTableHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1hm2IOModConfigDigOutputEntryHM2-IOMODULE-MIB
1.3.6.1.4.1.248.11.100.1.1.3.1.3hm2IOModConfigDigOutputLogEventHM2-IOMODULE-MIB