HM2-INDUSTRIAL-PROTOCOLS-MIB :: hm2ModbusTcpServerAdminStatus

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHM2-INDUSTRIAL-PROTOCOLS-MIBhm2ModbusTcpServerAdminStatus

hm2ModbusTcpServerAdminStatus

Module: HM2-INDUSTRIAL-PROTOCOLS-MIB

OID (symbolic): HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2ModbusTcpServerAdminStatus

OID (numeric): 1.3.6.1.4.1.248.11.101.1.4.1.1

Node type: OBJECT-TYPE

Type: HmEnabledStatus

Access: read-write

Description: Enables/disables the Modbus TCP server functionality on this device. If disabled(2), the Modbus TCP Server is deactivated, but the Modbus MIBs can be accessed. The default value is disabled.

What is hm2ModbusTcpServerAdminStatus?

Enables or disables the Modbus TCP server on the switch; disabled(2) deactivates Modbus access while the Modbus MIB objects stay SNMP-readable. Defaults to disabled, so an admin bringing up Modbus polling from a PLC/HMI must enable it first.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.101.1.4.1.1
snmpwalk -v2c -c public <target> HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2ModbusTcpServerAdminStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.101.1.4.1.1.1
snmpget -v2c -c public <target> HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2ModbusTcpServerAdminStatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.101.1.4.1.1.1 s <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch (IEC 61850 MMS server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2ModbusTcpServerAdminStatus OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (IEC 61850 MMS server) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHM2-TC-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.101hm2IndustrialProtocolsMibHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1hm2IndustrialProtocolsMibObjectsHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1.4hm2ModbusGroupHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1.4.1hm2ModbusConfigGroupHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1.4.1.1hm2ModbusTcpServerAdminStatusHM2-INDUSTRIAL-PROTOCOLS-MIB