hm2EtherNetIPAdminStatus

Module: HM2-INDUSTRIAL-PROTOCOLS-MIB

OID (symbolic): HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2EtherNetIPAdminStatus

OID (numeric): 1.3.6.1.4.1.248.11.101.1.3.1.1

Node type: OBJECT-TYPE

Type: HmEnabledStatus

Access: read-write

Description: Enables/disables the EtherNet/IP(TM) operation on this device. If disabled, the EtherNet/IP protocol is deactivated, but the EtherNet/IP MIBs can be accessed. The default value is disabled.

What is hm2EtherNetIPAdminStatus?

Turns EtherNet/IP support on or off for the switch; disabled deactivates the protocol while leaving its MIB objects SNMP-readable. Defaults to disabled, so an admin integrating the switch into a Rockwell/Allen-Bradley EtherNet/IP network must enable it explicitly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.248.11.101.1.3.1.1
snmpwalk -v2c -c public <target> HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2EtherNetIPAdminStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.248.11.101.1.3.1.1.1
snmpget -v2c -c public <target> HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2EtherNetIPAdminStatus.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.248.11.101.1.3.1.1.1 s <value>

Start monitoring Hirschmann HiOS industrial Ethernet switch (IEC 61850 MMS server) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HM2-INDUSTRIAL-PROTOCOLS-MIB::hm2EtherNetIPAdminStatus OID value, configure state conditions and alerts, and monitor any Hirschmann HiOS industrial Ethernet switch (IEC 61850 MMS server) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.248hirschmannHM2-TC-MIB
1.3.6.1.4.1.248.11hm2ConfigurationMibsHM2-TC-MIB
Numeric OIDNameModule
1.3.6.1.4.1.248.11.101hm2IndustrialProtocolsMibHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1hm2IndustrialProtocolsMibObjectsHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1.3hm2EthernetIPGroupHM2-INDUSTRIAL-PROTOCOLS-MIB
1.3.6.1.4.1.248.11.101.1.3.1hm2EthernetIPConfigGroupHM2-INDUSTRIAL-PROTOCOLS-MIB