HH3C-STACK-MIB :: hh3cStackLinkDelayInterval

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › HH3C-STACK-MIB › hh3cStackLinkDelayInterval

hh3cStackLinkDelayInterval

Module: HH3C-STACK-MIB

OID (symbolic): HH3C-STACK-MIB::hh3cStackLinkDelayInterval

OID (numeric): 1.3.6.1.4.1.25506.2.91.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The delay time for a device in a stack to report the change of stack port link status. If the delay time is configured, a device in a stack will not report the change immediately when the stack port link status changes to down. During the delay period, if the stack port link status is resumed, the device will ignore the current change of the stack port link status. If the stack port link status is not resumed after the delay time, the device will report the change. 0 means no delay, namely, the device will report the change as soon as the stack port link status changes to down.

0: no delay 200-2000(ms): delay time

What is hh3cStackLinkDelayInterval?

This sets, in milliseconds, how long a stack member waits before reporting a stack port link going down, giving a brief chance for the link to recover before triggering topology changes. An admin raises this from its default of 0, meaning no delay, to filter out brief link flaps on stack interconnects so they don't trigger unnecessary stack topology recalculations. For example, setting this to 500 means a one-time 300ms link blip on a stack port would be ignored rather than reported as a link-down event.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.91.1.6
snmpwalk -v2c -c public <target> HH3C-STACK-MIB::hh3cStackLinkDelayInterval

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.91.1.6.1
snmpget -v2c -c public <target> HH3C-STACK-MIB::hh3cStackLinkDelayInterval.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.25506.2.91.1.6.1 i <value>

Start monitoring H3C stackable switch running IRF (e.g. S5500/S7500/S12500 series) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-STACK-MIB::hh3cStackLinkDelayInterval OID value, configure state conditions and alerts, and monitor any H3C stackable switch running IRF (e.g. S5500/S7500/S12500 series) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.25506hh3cHH3C-OID-MIB
1.3.6.1.4.1.25506.2hh3cCommonHH3C-OID-MIB
1.3.6.1.4.1.25506.2.91hh3cStackHH3C-OID-MIB
Numeric OIDNameModule
1.3.6.1.4.1.25506.2.91.1hh3cStackGlobalConfigHH3C-STACK-MIB
1.3.6.1.4.1.25506.2.91.1.6hh3cStackLinkDelayIntervalHH3C-STACK-MIB