-- ================================================================= -- Copyright (C) 2008 by H3C TECHNOLOGIES. All rights reserved. -- -- Description: stack mib -- Reference: STACK-MIB -- Version: V1.0 -- History: -- V1.0 created by ranbin -- Initial version 2008-04-30 -- ================================================================= HH3C-STACK-MIB DEFINITIONS ::= BEGIN IMPORTS hh3cCommon FROM HH3C-OID-MIB entPhysicalIndex FROM ENTITY-MIB Integer32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; hh3cStack MODULE-IDENTITY LAST-UPDATED "200804301650Z" -- 30th April, 2007 at 16:50 GMT ORGANIZATION "Hangzhou H3C Technologies Co., Ltd." CONTACT-INFO "Platform Team H3C Technologies Co., Ltd. Hai-Dian District Beijing P.R. China Http://www.h3c.com Zip:100085" DESCRIPTION "This MIB is used to manage STM (Stack Topology Management) information for IRF (Intelligent Resilient Framework) device. This MIB is applicable to products which support IRF. Some objects in this MIB may be used only for some specific products, so users should refer to the related documents to acquire more detailed information." REVISION "200804301650Z" -- 30th April, 2007 at 16:50 GMT DESCRIPTION "The initial revision of this MIB module." ::= { hh3cCommon 91 } -- Scalar MIB objects, which are considered as global variables -- Global Level Configuration hh3cStackGlobalConfig OBJECT IDENTIFIER ::= { hh3cStack 1 } hh3cStackMaxMember OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of members in a stack." ::= { hh3cStackGlobalConfig 1 } hh3cStackMemberNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of members currently in a stack." ::= { hh3cStackGlobalConfig 2 } hh3cStackMaxConfigPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The highest priority that can be configured for a member in a stack." ::= { hh3cStackGlobalConfig 3 } hh3cStackAutoUpdate OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "The function for automatically updating the image from master to slave. When a new device tries to join a stack, the image version is checked. When this function is enabled, if the image version of the new device is different from that of the master, the image of the new device will be updated to be consistent with that of the master. When this function is disabled, the new device can not join the stack if the image version of the new device is different from that of the master. disabled: disable auto update function enabled: enable auto update function" ::= { hh3cStackGlobalConfig 4 } hh3cStackMacPersistence OBJECT-TYPE SYNTAX INTEGER { notPersist(1), persistForSixMin(2), persistForever(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "The mode of bridge MAC address persistence. When a stack starts, the bridge MAC address of master board will be used as that of the stack. If the master board leaves the stack, the bridge MAC address of the stack will change based on the mode of bridge MAC address persistence. notPersist: The bridge MAC address of the new master board will be used as that of the stack immediately. persistForSixMin: The bridge MAC address will be reserved for six minutes. In this period, if the master board which has left the stack rejoins the stack, the bridge MAC address of the stack will not change. Otherwise, the bridge MAC address of the new master board will be used as that of the stack. persistForever: Whether the master leaves or not, the bridge MAC address of the stack will never change." ::= { hh3cStackGlobalConfig 5 } hh3cStackLinkDelayInterval OBJECT-TYPE SYNTAX INTEGER (0 | 200..2000) UNITS "millisecond" MAX-ACCESS read-write STATUS current DESCRIPTION "The delay time for a device in a stack to report the change of stack port link status. If the delay time is configured, a device in a stack will not report the change immediately when the stack port link status changes to down. During the delay period, if the stack port link status is resumed, the device will ignore the current change of the stack port link status. If the stack port link status is not resumed after the delay time, the device will report the change. 0 means no delay, namely, the device will report the change as soon as the stack port link status changes to down. 0: no delay 200-2000(ms): delay time" ::= { hh3cStackGlobalConfig 6 } hh3cStackTopology OBJECT-TYPE SYNTAX INTEGER { chainConn(1), ringConn(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The topology of the stack. chainConn: chain connection ringConn: ring connection" ::= { hh3cStackGlobalConfig 7 } -- Device Level Configuration hh3cStackDeviceConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackDeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage device information in a stack." ::= { hh3cStack 2 } hh3cStackDeviceConfigEntry OBJECT-TYPE SYNTAX Hh3cStackDeviceConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage device information in a stack." INDEX { entPhysicalIndex } ::= { hh3cStackDeviceConfigTable 1 } Hh3cStackDeviceConfigEntry ::= SEQUENCE { hh3cStackMemberID Integer32, hh3cStackConfigMemberID Integer32, hh3cStackPriority Integer32, hh3cStackPortNum Integer32, hh3cStackPortMaxNum Integer32 } hh3cStackMemberID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The member ID of the device in a stack." ::= { hh3cStackDeviceConfigEntry 1 } hh3cStackConfigMemberID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The configured member ID of the device. The valid value ranges from 1 to the value of hh3cStackMaxMember. After the member ID is configured for a device, if this ID is not the same with that of another device, the ID will be used as the member ID of the device when the device reboots. If a same ID exists, the member ID of the device will be set as another exclusive ID automatically." ::= { hh3cStackDeviceConfigEntry 2 } hh3cStackPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The priority of a device in a stack. The valid value ranges from 1 to the value of hh3cStackMaxConfigPriority." ::= { hh3cStackDeviceConfigEntry 3 } hh3cStackPortNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of stack ports which is enabled in a device." ::= { hh3cStackDeviceConfigEntry 4 } hh3cStackPortMaxNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum number of stack ports in a device." ::= { hh3cStackDeviceConfigEntry 5 } -- Board Level Configuration hh3cStackBoardConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackBoardConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage board information of the device in a stack." ::= { hh3cStack 3 } hh3cStackBoardConfigEntry OBJECT-TYPE SYNTAX Hh3cStackBoardConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage board information of the device in a stack." INDEX { entPhysicalIndex } ::= { hh3cStackBoardConfigTable 1 } Hh3cStackBoardConfigEntry ::= SEQUENCE { hh3cStackBoardRole INTEGER, hh3cStackBoardBelongtoMember Integer32 } hh3cStackBoardRole OBJECT-TYPE SYNTAX INTEGER { slave(1), master(2), loading(3), other(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The role of the board in a stack. slave: slave board master: master board loading: slave board whose image version is different from that of the master board. other: other" ::= { hh3cStackBoardConfigEntry 1 } hh3cStackBoardBelongtoMember OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The member ID of the device where the current board resides in a stack." ::= { hh3cStackBoardConfigEntry 2 } -- stack port Information hh3cStackPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage stack port information of a device in a stack." ::= { hh3cStack 4 } hh3cStackPortInfoEntry OBJECT-TYPE SYNTAX Hh3cStackPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage stack port information of a device in a stack." INDEX { hh3cStackMemberID, hh3cStackPortIndex } ::= { hh3cStackPortInfoTable 1 } Hh3cStackPortInfoEntry ::= SEQUENCE { hh3cStackPortIndex Integer32, hh3cStackPortEnable INTEGER, hh3cStackPortStatus INTEGER, hh3cStackNeighbor Integer32 } hh3cStackPortIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS accessible-for-notify STATUS current DESCRIPTION "The index of a stack port of the device in a stack." ::= { hh3cStackPortInfoEntry 1 } hh3cStackPortEnable OBJECT-TYPE SYNTAX INTEGER { disabled(1), enabled(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The status of the stack port of the device in a stack. If no physical port is added to the stack port, its status is 'disabled'; otherwise, its status is 'enabled'. disabled: The stack port is disabled. enabled: The stack port is enabled." ::= { hh3cStackPortInfoEntry 2 } hh3cStackPortStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), silent(3), disabled(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The link status of the stack port of the device in a stack. up: The link status of a stack port with reasonable physical connection is up. down: The link status of a stack port without physical connection is down. silent: The link status of a stack port which can not be used normally is silent. disabled: The link status of a stack port in disabled status is disabled." ::= { hh3cStackPortInfoEntry 3 } hh3cStackNeighbor OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The member ID of the stack port's neighbor in a stack. 0 means no neighbor exists." ::= { hh3cStackPortInfoEntry 4 } -- Physical port Information hh3cStackPhyPortInfoTable OBJECT-TYPE SYNTAX SEQUENCE OF Hh3cStackPhyPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage the information for physical ports which can be used for physical connection of stack port in a stack." ::= { hh3cStack 5 } hh3cStackPhyPortInfoEntry OBJECT-TYPE SYNTAX Hh3cStackPhyPortInfoEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains objects to manage the information for physical ports which can be used for physical connection of stack port in a stack." INDEX { entPhysicalIndex } ::= { hh3cStackPhyPortInfoTable 1 } Hh3cStackPhyPortInfoEntry ::= SEQUENCE { hh3cStackBelongtoPort Integer32 } hh3cStackBelongtoPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The index of the stack port to which the physical port is added. 0 means the physical port is not added to any stack port. The value will be valid after the device in the stack reboots." ::= { hh3cStackPhyPortInfoEntry 1 } -- -- Notification definitions -- -- ================================================================= -- Traps are defined below. hh3cStackTrap OBJECT IDENTIFIER ::= { hh3cStack 6 } -- All objects used for TRAP only are defined here. hh3cStackTrapOjbects OBJECT IDENTIFIER ::= { hh3cStackTrap 0 } hh3cStackPortLinkStatusChange NOTIFICATION-TYPE OBJECTS { hh3cStackMemberID, hh3cStackPortIndex, hh3cStackPortStatus } STATUS current DESCRIPTION "The hh3cStackPortLinkStatusChange trap indicates that the link status of the stack port has changed." ::= { hh3cStackTrapOjbects 1 } hh3cStackTopologyChange NOTIFICATION-TYPE OBJECTS { hh3cStackTopology } STATUS current DESCRIPTION "The hh3cStackTopologyChange trap indicates that the topology type of the stack has changed." ::= { hh3cStackTrapOjbects 2 } END