All MIBs › HH3C-FC-ZONE-SERVER-MIB › hh3cFcZsServerLastResult
hh3cFcZsServerLastResult
Module: HH3C-FC-ZONE-SERVER-MIB
OID (symbolic): HH3C-FC-ZONE-SERVER-MIB::hh3cFcZsServerLastResult
OID (numeric): 1.3.6.1.4.1.25506.2.127.9.1.1.1.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Current operational status of the latest configuration in this VSAN:
'none' - No corresponding operation has been performed yet. 'success' - The configuration was performed successfully. 'busy' - The configuration was performed unsuccessfully, because the system is busy with another zoning operation. 'noSupportInFabric' - The configuration was performed unsuccessfully, because one or more switches in this Fabric don't support Enhanced zoning. 'noSupportInBasic' - The configuration was performed unsuccessfully, because it is not supported in Basic mode. 'noSupportInEnhanced' - The configuration was performed unsuccessfully, because it is not supported in Enhanced mode. 'activeZoneSetTooBig' - The configuration was performed unsuccessfully, because the Active Zone Set is too large to be supported. 'otherFault' - The configuration was performed unsuccessfully for other reasons.
What is hh3cFcZsServerLastResult?
This read-only INTEGER reports the outcome of the most recent zoning configuration operation on a VSAN, such as success(2), busy(3) if another zoning operation was already running, or activeZoneSetTooBig(7) if the configuration exceeded a size limit. An admin checks this after pushing a zoning change to confirm it actually applied rather than silently failing.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.25506.2.127.9.1.1.1.1.6 snmpwalk -v2c -c public <target> HH3C-FC-ZONE-SERVER-MIB::hh3cFcZsServerLastResult
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.25506.2.127.9.1.1.1.1.6.1 snmpget -v2c -c public <target> HH3C-FC-ZONE-SERVER-MIB::hh3cFcZsServerLastResult.1
Start monitoring H3C Fibre Channel SAN switches with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HH3C-FC-ZONE-SERVER-MIB::hh3cFcZsServerLastResult OID value, configure state conditions and alerts, and monitor any H3C Fibre Channel SAN switches from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.25506 | hh3c | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.2 | hh3cCommon | HH3C-OID-MIB |
| 1.3.6.1.4.1.25506.2.127 | hh3cSan | HH3C-VSAN-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.25506.2.127.9 | hh3cFcZoneServer | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.9.1 | hh3cFcZoneMibObjects | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.9.1.1 | hh3cFcZsConfiguration | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.9.1.1.1 | hh3cFcZsServerTable | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.9.1.1.1.1 | hh3cFcZsServerEntry | HH3C-FC-ZONE-SERVER-MIB |
| 1.3.6.1.4.1.25506.2.127.9.1.1.1.1.6 | hh3cFcZsServerLastResult | HH3C-FC-ZONE-SERVER-MIB |