HDSL2-SHDSL-LINE-MIB :: hdsl2ShdslEndpointCurrAtn

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsHDSL2-SHDSL-LINE-MIBhdsl2ShdslEndpointCurrAtn

hdsl2ShdslEndpointCurrAtn

Module: HDSL2-SHDSL-LINE-MIB

OID (symbolic): HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointCurrAtn

OID (numeric): 1.3.6.1.2.1.10.48.1.5.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The current loop attenuation for this endpoint as reported in a Network or Customer Side Performance Status message.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.48.1.5.1.1
snmpwalk -v2c -c public <target> HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointCurrAtn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.48.1.5.1.1.1
snmpget -v2c -c public <target> HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointCurrAtn.1

Start monitoring Vendor-neutral DSL modem/DSLAM/router, any manufacturer (HDSL2/G.SHDSL, RFC 4319) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointCurrAtn OID value, configure state conditions and alerts, and monitor any Vendor-neutral DSL modem/DSLAM/router, any manufacturer (HDSL2/G.SHDSL, RFC 4319) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing HDSL2-SHDSL-LINE-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hdsl2ShdslEndpointCurrAtn into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current loop attenuation, in dB, measured on this SHDSL line endpoint. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if attenuation exceeds 40 dB, which typically signals a marginal or degrading copper line. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.48hdsl2ShdslMIBHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1hdsl2ShdslMibObjectsHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.5hdsl2ShdslEndpointCurrTableHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.5.1hdsl2ShdslEndpointCurrEntryHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.5.1.1hdsl2ShdslEndpointCurrAtnHDSL2-SHDSL-LINE-MIB