hdsl2ShdslEndpointAlarmConfProfile

Module: HDSL2-SHDSL-LINE-MIB

OID (symbolic): HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointAlarmConfProfile

OID (numeric): 1.3.6.1.2.1.10.48.1.4.1.3

Node type: OBJECT-TYPE

Type: SnmpAdminString

Access: read-write

Description: This object configures the alarm threshold values to be used for this segment endpoint. The values are obtained from the alarm configuration profile referenced by this object. The value of this object is the index of the referenced profile in the hdsl2ShdslEndpointAlarmConfProfileTable, or NULL (a zero-length SnmpAdminString). If the value is a zero-length SnmpAdminString, the endpoint uses the default Alarm Configuration Profile for the associated span as per the hdsl2ShdslSpanConfAlarmProfile object in the hdsl2ShdslSpanConfTable. The default value of this object is a zero-length SnmpAdminString.

Any attempt to set this object to a value that is not the value of the index for an active entry in the profile table, hdsl2ShdslEndpointAlarmConfProfileTable, MUST be rejected.

What is hdsl2ShdslEndpointAlarmConfProfile?

Selects which alarm configuration profile's thresholds apply to this specific segment endpoint, overriding the span-level default when set to a non-empty value. Setting it to a profile index that isn't an active row is rejected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.48.1.4.1.3
snmpwalk -v2c -c public <target> HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointAlarmConfProfile

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.48.1.4.1.3.1
snmpget -v2c -c public <target> HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointAlarmConfProfile.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.2.1.10.48.1.4.1.3.1 s <value>

Start monitoring Vendor-neutral DSL modem/DSLAM/router, any manufacturer (HDSL2/G.SHDSL, RFC 4319) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the HDSL2-SHDSL-LINE-MIB::hdsl2ShdslEndpointAlarmConfProfile OID value, configure state conditions and alerts, and monitor any Vendor-neutral DSL modem/DSLAM/router, any manufacturer (HDSL2/G.SHDSL, RFC 4319) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
Numeric OIDNameModule
1.3.6.1.2.1.10.48hdsl2ShdslMIBHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1hdsl2ShdslMibObjectsHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.4hdsl2ShdslEndpointConfTableHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.4.1hdsl2ShdslEndpointConfEntryHDSL2-SHDSL-LINE-MIB
1.3.6.1.2.1.10.48.1.4.1.3hdsl2ShdslEndpointAlarmConfProfileHDSL2-SHDSL-LINE-MIB