H150E-MIB :: h150eCdrTftpClientTimer

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsH150E-MIBh150eCdrTftpClientTimer

h150eCdrTftpClientTimer

Module: H150E-MIB

OID (symbolic): H150E-MIB::h150eCdrTftpClientTimer

OID (numeric): 1.3.6.1.4.1.231.7.2.9.5.7

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: cycle time in minutes for initiating CDR output, max value 1439 minutes (23hours,59minutes) (only relevant for TFTP client mode)

What is h150eCdrTftpClientTimer?

Sets the interval, in minutes (up to 1439, i.e. just under 24 hours), between successive CDR export cycles in TFTP client mode - how often the device pushes its collected call records to the configured TFTP server.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.7
snmpwalk -v2c -c public <target> H150E-MIB::h150eCdrTftpClientTimer

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.7.1
snmpget -v2c -c public <target> H150E-MIB::h150eCdrTftpClientTimer.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.2.9.5.7.1 i <value>

Start monitoring Siemens HiPath 3000 / Hicom 150E/H PBX with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H150E-MIB::h150eCdrTftpClientTimer OID value, configure state conditions and alerts, and monitor any Siemens HiPath 3000 / Hicom 150E/H PBX from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.2pnH150E-MIB
1.3.6.1.4.1.231.7.2.9h150eOfficeH150E-MIB
1.3.6.1.4.1.231.7.2.9.5h150eCdrConfigGroupH150E-MIB
1.3.6.1.4.1.231.7.2.9.5.7h150eCdrTftpClientTimerH150E-MIB