H150E-MIB :: h150eCdrOutputMode

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsH150E-MIBh150eCdrOutputMode

h150eCdrOutputMode

Module: H150E-MIB

OID (symbolic): H150E-MIB::h150eCdrOutputMode

OID (numeric): 1.3.6.1.4.1.231.7.2.9.5.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: CDR (Call Detailed Record) output mode: V24-Port (1): the PABX is permanently connected over a V.24 connection to an extern application and sends each CDR immidiatly NOTE: no write access UPN-Port (2): the PABX is permanently connected over terminal adapter (PPM) connection to an extern application and sends each CDR immidiatly NOTE: no write access PCVPL-Port (3): the PEBX is permanently connected over a CorNet TS connection to an extern application (PCVPL) and sends each CDR immidiatly NOTE: no write access TFTP-Client (4): the PABX sends the collected CDRs to the administrated TFTP-Server TFTP-Server (5): an extern TFTP client can request the collected CDRs TCP-Client (6): the PABX is permanently connected to an extern TCP server and sends each CDR immidiatly NoOutput (7): no output for CDR

What is h150eCdrOutputMode?

Selects how the device delivers Call Detail Records: permanent connections like v24port(1), uPNport(2), or pCVPLport(3) send each CDR immediately and are read-only status values, while tftpClient(4)/tftpServer(5)/tcpClient(6) are configurable delivery methods and noOutput(7) disables CDR export entirely.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.10
snmpwalk -v2c -c public <target> H150E-MIB::h150eCdrOutputMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.10.1
snmpget -v2c -c public <target> H150E-MIB::h150eCdrOutputMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.2.9.5.10.1 i <value>

Start monitoring Siemens HiPath 3000 / Hicom 150E/H PBX with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H150E-MIB::h150eCdrOutputMode OID value, configure state conditions and alerts, and monitor any Siemens HiPath 3000 / Hicom 150E/H PBX from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.2pnH150E-MIB
1.3.6.1.4.1.231.7.2.9h150eOfficeH150E-MIB
1.3.6.1.4.1.231.7.2.9.5h150eCdrConfigGroupH150E-MIB
1.3.6.1.4.1.231.7.2.9.5.10h150eCdrOutputModeH150E-MIB