H150E-MIB :: h150eCdrElementSeparator

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsH150E-MIBh150eCdrElementSeparator

h150eCdrElementSeparator

Module: H150E-MIB

OID (symbolic): H150E-MIB::h150eCdrElementSeparator

OID (numeric): 1.3.6.1.4.1.231.7.2.9.5.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Separator between the different elements of one CDR: pipe (0x7c): '|' semicolon (0x3b): ';' blank (0x20): ' ' NOTE: no write access for blank

What is h150eCdrElementSeparator?

Selects the character used to separate individual fields within one Call Detail Record: pipe(124) for '|', semicolon(59) for ';', or blank(32) for a space; note the blank option is read-only and can't actually be set via SNMP.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.2
snmpwalk -v2c -c public <target> H150E-MIB::h150eCdrElementSeparator

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.2.9.5.2.1
snmpget -v2c -c public <target> H150E-MIB::h150eCdrElementSeparator.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.7.2.9.5.2.1 i <value>

Start monitoring Siemens HiPath 3000 / Hicom 150E/H PBX with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the H150E-MIB::h150eCdrElementSeparator OID value, configure state conditions and alerts, and monitor any Siemens HiPath 3000 / Hicom 150E/H PBX from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.2pnH150E-MIB
1.3.6.1.4.1.231.7.2.9h150eOfficeH150E-MIB
1.3.6.1.4.1.231.7.2.9.5h150eCdrConfigGroupH150E-MIB
1.3.6.1.4.1.231.7.2.9.5.2h150eCdrElementSeparatorH150E-MIB