All MIBs › GDCSCM-MIB › scmRedundantTimeOut
scmRedundantTimeOut
Module: GDCSCM-MIB
OID (symbolic): GDCSCM-MIB::scmRedundantTimeOut
OID (numeric): 1.3.6.1.4.1.498.3.6.2.16
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: This object is used to set the time period, represented in seconds, in which the redundant SCM will wait after not receiving express polls from the primary SCM before it takes contol of the management buss. When set to zero, the redundant SCM will ignore the loss of express polls. The default is zero.
What is scmRedundantTimeOut?
Sets, in seconds, how long a redundant SCM waits without receiving express polls from the primary before taking over the management bus; a value of zero (the default) makes it ignore lost polls and never fail over automatically.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.3.6.2.16 snmpwalk -v2c -c public <target> GDCSCM-MIB::scmRedundantTimeOut
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.3.6.2.16.1 snmpget -v2c -c public <target> GDCSCM-MIB::scmRedundantTimeOut.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.498.3.6.2.16.1 i <value>
Start monitoring General DataComm (GDC) SCM (Shelf Control Module)-managed multiplexing/access shelf with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCSCM-MIB::scmRedundantTimeOut OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) SCM (Shelf Control Module)-managed multiplexing/access shelf from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| 1.3.6.1.4.1.498.3 | sc | DMA200-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.3.6 | scmSystem | GDCSCM-MIB |
| 1.3.6.1.4.1.498.3.6.2 | scmMaster | GDCSCM-MIB |
| 1.3.6.1.4.1.498.3.6.2.16 | scmRedundantTimeOut | GDCSCM-MIB |