All MIBs › GDCDS1-MIB › csuIndicatorTNS
csuIndicatorTNS
Module: GDCDS1-MIB
OID (symbolic): GDCDS1-MIB::csuIndicatorTNS
OID (numeric): 1.3.6.1.4.1.498.2.3.1.10
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: This object is the Terminal No Signal indicator. It indicates whether the CSU is or is not receiving an equipment signal. GDCPRODUCT STATUS BAR 551 TNS 551 (unframed) TNS 552a none 552a-1 none
What is csuIndicatorTNS?
Shows whether the CSU is currently receiving a signal from the attached terminal equipment, matching the 'TNS' status-bar light on a 551 unit; like csuIndicatorTSY, it applies only to the 551 product.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.498.2.3.1.10 snmpwalk -v2c -c public <target> GDCDS1-MIB::csuIndicatorTNS
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.498.2.3.1.10.1 snmpget -v2c -c public <target> GDCDS1-MIB::csuIndicatorTNS.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> csuIndicatorTNS.1
Start monitoring General DataComm (GDC) DS1/T1 CSU equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GDCDS1-MIB::csuIndicatorTNS OID value, configure state conditions and alerts, and monitor any General DataComm (GDC) DS1/T1 CSU equipment from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.498 | gdc | DMA200-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.498.2 | csu | GDCDS1-MIB |
| 1.3.6.1.4.1.498.2.3 | csuIndicatorTable | GDCDS1-MIB |
| 1.3.6.1.4.1.498.2.3.1 | csuIndicatorEntry | GDCDS1-MIB |
| 1.3.6.1.4.1.498.2.3.1.10 | csuIndicatorTNS | GDCDS1-MIB |