GANDALF-ENTERPRISE-MIB :: hubResetAction

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › GANDALF-ENTERPRISE-MIB › hubResetAction

hubResetAction

Module: GANDALF-ENTERPRISE-MIB

OID (symbolic): GANDALF-ENTERPRISE-MIB::hubResetAction

OID (numeric): 1.3.6.1.4.1.64.1.2.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Restart the hub if selecting reset.

What is hubResetAction?

A read-write control an admin sets to reset(2) to remotely restart the hub via SNMP, or leaves at noreset(1) for normal operation. This is useful for recovering a hung or misbehaving hub without needing physical access to the device.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.64.1.2.10
snmpwalk -v2c -c public <target> GANDALF-ENTERPRISE-MIB::hubResetAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.64.1.2.10.1
snmpget -v2c -c public <target> GANDALF-ENTERPRISE-MIB::hubResetAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.64.1.2.10.1 i <value>

Start monitoring Legacy Gandalf Technologies hub equipment with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the GANDALF-ENTERPRISE-MIB::hubResetAction OID value, configure state conditions and alerts, and monitor any Legacy Gandalf Technologies hub equipment from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.64gandalfGANDALF-ENTERPRISE-MIB
1.3.6.1.4.1.64.1gandalf_hubGANDALF-ENTERPRISE-MIB
1.3.6.1.4.1.64.1.2hmSelfTestCapabilityGANDALF-ENTERPRISE-MIB
1.3.6.1.4.1.64.1.2.10hubResetActionGANDALF-ENTERPRISE-MIB